| Manufacturer | TimeMark |
| Manufacturer Product Number | EX2594 |
| Description | Phase Monitor Relay; 3-Phase; 380V AC; 300...400V AC; 2C DPDT |
| Datasheet | Download Datasheet |
The TimeMark EX2594 is a 3-phase monitor for 380 V AC, 50 Hz systems. It drops its output relay out on phase loss, phase reversal and undervoltage and resets once the fault clears.
Trip points: undervoltage 300-400 V AC. Adjustment: field adjustable. Trip delay: phase loss / reversal 0.05 s fixed. Reset: automatic.
Output: 2C DPDT, 3 A at 480/600 V AC 80% PF; 10 A at 240 V AC 80% PF resistive. Mounting: surface mount. Indicator: FAILURE INDICATOR LED.
| Category | |
| Manufacturer | TimeMark |
| Model | 2594 |