Across Open Contacts: 500Vrms Between Mutally Insulated Points: 1500Vrms
Insulation Resistance
1,000 Mohms min @ 500VDC
Temperature
Operating: -20 to 55°C (-4 to 131°F) Storage: -40 to 85°C (-40 to 185°F)
Life Expectancy
Electrical (full load operations): 100,000 Mechanical (no load operations): 10,000,000
Enclosure
Opaque Polycarbonate
Series Features
388 Series - True Off Relay
Series Description:The 388 true off timers are square base, bladed products. Solid state circuitry combined with a magnetic latching relay allow this product to time when no power is applied. Contacts transfer when power is applied. Timing begins when power is removed. Contacts return to the home position at the end of the timing cycle. No external control switch is needed to initiate timing. The package on this series is typically socket mounted.