On / Off Recycling (Pulse Generator) approx. 50% ratio
Logic / Function Type
ON Time First
Adjustment
Onboard Adjust
Termination
0.25in. Male Quick Connect Terminals
Series Features
Recycling (Flasher) KSD3 Digi-Timer Timing Module
Series Description:The KSD3 Digi-Timer is a cost effective approach for ON/OFF recycling applications. The ON time is always equal to the OFF time--an adjustment of a potentiometer will change the time delays of both ON and OFF times equally.
Operation:(Recycling Flasher - ON Time First) Upon application of input voltage, the output energizes and the T1, ON time begins. At the end of the ON time, the output de-energizes and the T2 OFF time begins. At the end of the OFF time, the output energizes and the cycle repeats as long as input voltage is applied. Reset: Removing input voltage resets the output and time delays, and returns the sequence to the ON time.