Product Description
Description: Time Delay Relay • Interval • Input Voltage : 230 VAC • Timing Range; 1 - 100 min • Mounting ; Surface Mount • Contact Configuration; 1C SPDT • Output Current; 30 Amps • Mode of Operation; Interval (Single Pulse on Operate) • Adjustment; External Adjust • Termination; 0.25in. Male Quick Connect Terminals • Notes:; Potentiometer / Resistor Required (ordered seperately)
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage | 230 VAC |
Timing Range | 1 - 100 min |
Mounting | Surface Mount |
Contact Configuration | 1C SPDT |
Output Current | 30 Amps |
Mode of Operation | Interval (Single Pulse on Operate) |
Adjustment | External Adjust |
Termination | 0.25in. Male Quick Connect Terminals |
Notes: | Potentiometer / Resistor Required (ordered seperately) |
Series Features |
Timer - Interval HRDI Series |
Series Description: The HRDI Series combines an electromechanical relay output with microcontroller timing circuitry. It offers 12 to 230V operation in five ranges and factory fixed, external, or onboard adjustable time delays with a repeat accuracy of ±0.5%. The output contact rating allows for direct operation of heavy loads, such as compressors, pumps, blower motors, heaters, etc. This series is ideal for OEM applications where cost is a factor. |
Operation: (Interval) Upon application of input voltage, the time delay begins. The output relay is energized during the time delay. At the end of the time delay, the output de-energizes and remains de-energized until input voltage is removed. Reset: Removing input voltage resets the time delay and the output. |
|