Product Description
Description: Time Delay Relay • Delay on Break • Input Voltage : 120 VAC • Timing Range; 120 sec • Mounting ; Surface Mount • Contact Configuration; 1C SPDT • Output Current; 10 Amps • Mode of Operation; Delay on Break (Release) • Adjustment; Fixed • Termination; 0.25in. Male Quick Connect Terminals
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage | 120 VAC |
Timing Range | 120 sec |
Mounting | Surface Mount |
Contact Configuration | 1C SPDT |
Output Current | 10 Amps |
Mode of Operation | Delay on Break (Release) |
Adjustment | Fixed |
Termination | 0.25in. Male Quick Connect Terminals |
Series Features |
Timer - Delay-on-Break ORB Series |
Series Description: The ORB Series open PCB construction offers the user good economy without sacrificing performance and reliability. The output relay is available in isolated, 10A, DPDT or SPDT forms. The time delay may be ordered as factory fixed, onboard knob, or external adjustment. All connections are 0.25 in. (6.35 mm) male quick connect terminals . |
Operation: (Delay-on-Break) Input voltage must be applied before and during timing. Upon closure of the initiate switch, the output relay energizes. The time delay begins when the initiate switch is opened (trailing edge triggered). The output remains energized during timing. At the end of the time delay, the output de-energizes. The output will energize if the initiate switch is closed when input voltage is applied. Reset: Reclosing the initiate switch during timing resets the time delay. Loss of input voltage resets the time delay and output. |
|