Breakdown Voltage (Initial) : Between Open Contacts
750 Vrms for 1min. (Detection current: 10mA.)
Breakdown Voltage (Initial) : Between Contact And Coil
1,000 Vrms for 1min. (Detection current: 10mA.)
Breakdown Voltage (Contact-Contact) (Initial)
1,000 Vrms for 1min. (Detection current: 10mA.)
Surge Breakdown Voltage (Initial): Between Contacts and Coil
1,500V (FCC)
Expected Life: Mechanical
Min. 108
Expected Life: Electrical
Min. 5×105 (1A 30V DC) Min. 1×105 (2A 30V DC)
Conditions
Ambient temperature: 40 to +70°C 40 to +158°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Series Features
DS2Y SERIES RELAYS
Series Description:Panasonics DS2Y Series Relays feature a high sensitivity of 200 mW nominal operating power and a high breakdown voltage of 1500 V FCC surge between open contacts. The DS2Y Series Relays are ideal for use in various applications, including medical equipment, security alarm systems, computer peripherals, and more.
The DS2Y Series Relay product line has been partially Not Recommended For New Design for DS2 parts.