Breakdown Voltage (Initial) : Between Open Contacts
750 Vrms for 1min. (Detection current: 10mA.)
Min. Switching Capacity
10µA 10mV DC
Breakdown Voltage (Initial) : Between Contact And Coil
1,500 Vrms for 1min. (Detection current: 10mA.)
Breakdown Voltage (Contact-Contact) (Initial)
1,000 Vrms for 1min. (Detection current: 10mA.)
Surge Breakdown Voltage (Initial): Between Open Contacts
1,500 V (10 x 160µs) (FCC Part 68)
Surge Breakdown Voltage (Initial): Between Contacts and Coil
2,500 V (2 x 10µs) (Telcordia)
Expected Life: Mechanical
Min. 5 x 107 (at 180 cpm)
Expected Life: Electrical
Min. 1 x 105 (1A 30V DC resistive) Min. 1 x 105 (3.5A inrush (250ms) / 1A 30V AC (cos?=0.4)) (ON/OFF=1s/9s)
Conditions
Ambient temperature: 40 to +85°C 40 to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Set Voltage
-
Reset Voltage
-
Series Features
GQ SERIES RELAYS TH TYPE
Series Description:Panasonic's GQ Series Relays TH Type are low profile (5.4mm height) signal relay which has a 2FormC (DPDT) contact arrangement and are available in both through-hole and surface mount options. The input for the GQ Series is available as either single-side stable or 1-coil latching. The single-side stable also features a high sensitivity coil version for a lower power consumption of only 100mW nominal operating power. Standard DC coil voltage options include 1.5V, 3V, 4.5V, 6V, 9V, 12V, and 24V.
The GQ Series Relays TH Type is similar to the standard GQ Series Relay, but is also capable of switching a 3.5A inrush load typically found in thermostat applications for 100K cycles.
Applications:Thermostat (HVAC temperature controller); Others, High-capacity control etc.
Small Size
Controlled 3.5 A Inrush Current Possible
2.4 Coil Voltage Type Newly Available DC Battery Operation