Breakdown Voltage (Initial) : Between Open Contacts
750 Vrms for 1min. (Detection current: 10mA.)
Breakdown Voltage (Initial) : Between Contact And Coil
1,500 Vrms for 1min. (Detection current: 10mA.)
Breakdown Voltage (Contact-Contact) (Initial)
1,000 Vrms for 1min. (Detection current: 10mA.)
Surge Breakdown Voltage (Initial): Between Open Contacts
1,500 V (10 x 160µs) (FCC Part 68)
Surge Breakdown Voltage (Initial): Between Contacts and Coil
2,500 V (2 x 10µs) (Telcordia)
Expected Life: Mechanical
Min. 5 x 107 (at 180 cpm)
Expected Life: Electrical
Min. 105 (1 A 30 V DC resistive), 105 (0.3 A 125 V AC resistive) (at 20 cpm)
Conditions
Ambient temperature: 40 to +85°C 40 to +185°F Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Set Voltage
-
Reset Voltage
-
Series Features
GN SERIES RELAYS
Series Description:Panasonic's GN Series Relays are narrow profile (5.7mm wide) signal relays with a 2FormC (DPDT) contact arrangement and are available in both through-hole and surface mount options. The input for the GN Series is available as either single-side stable or 1-coil latching. The single-side stable also features a high sensitivity coil version for a lower power consumption of only 100mW nominal operating power. Standard DC coil voltage options include 1.5V, 3V, 4.5V, 6V, 9V, 12V, and 24V.
Applications:Telecommunications And Measurement Equipment; Telephone Related Equipment; Household Electrical Appliance and Audio Visual Equipment; Security Equipment