Description: Power Relays • Rated Coil Voltage: 5 VDC • Contact Arrangement: 2A+2B DPST-NO+DPST-NC • Contact Current: 4 A • Operating Function : 2 coil latching • Terminal Type: PC Board • Protective Construction: Sealed
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 5 VDC |
Contact Arrangement | 2A+2B DPST-NO+DPST-NC |
Contact Current | 4 A |
Operating Function | 2 coil latching |
Terminal Type | PC Board |
Protective Construction | Sealed |
Rated Operating Power | 192 mW |
Accessories | Sockets are available. |
Operate Voltage (@20oC) | |
Release Voltage (at20°C) | |
Rated Operating Current [±10%] (at 20°C) | Set coil: 38.5 mA Reset coil: 38.5 mA |
Resistance [±10%] (at 20°C) | Set coil: 130 ? Reset coil: 130 ? |
Max. Allowable Voltage | 180% V of rated coil voltage (at 40°C) |
Contact Shape | Twin |
Contact Resistance (Initial) | Max. 50 m? (by voltage drop 6 V DC 1 A) |
Contact Material | Double layer contact of AgNi-AgSnO2 type + Au clad |
Contact Rating (Resistive Load) | 4 A 250 V AC, 3 A 30 V DC |
Max. Switching Power (Resistive Load) | 1,000 VA, 90 W |
Max. Switching Voltage | 250 V AC, 48 V DC |
Max. Switching Current | 4 A (AC), 3 A (DC) (30 to 48 V DC at less than 0.5 A) |
Min. Switching Load (Reference Value) | 100 µA 100 mV DC |
Insulation Resistance (Initial) | Min. 10,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 750 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact Sets | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 1,500 Vrms for 1 min (detection current: 10 mA) |
Operate Time (Initial) (At 20oC) | |
Release Time (Initial) (at 20°C) | |
Hock Resistance (Functional) | 490 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 3 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 4 mm) |
Mechanical Life | Min. 100x106 ope. (switching frequency: at 50 cps) |
Conditions | Ambient temperature: -55 to +65°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 200x103 ope. 3 A 30 V DC Min. 100x103 ope. 4 A 250 V AC |
Set Voltage | Max. 70% V of rated coil voltage (Initial) |
Reset Voltage | Max. 70% V of rated coil voltage (Initial) |
Time (Initial) (at 20°C 68°F) (Initial) | Max. 15 ms at rated coil voltage (without bounce) |
Reset Time (Initial) (at20°C 68°F) | Max. 15 ms at rated coil voltage (without bounce, without diode) |
Series Features |
S SERIES RELAYS |
Series Description: Panasonics S Series Polarized Power Relays use Panasonic's exclusive 4-gap balanced armature to realize high sensitivity, strong resistance to vibration and shock, and high reliability in a small package. These S Series Relays are available in 2 Form A 2 Form B, 3 Form A 1 Form B, or 4 Form A contact arrangements. The S Series Relays can provide wide-ranging control from 100uA 100mVDC to 4A 250VAC using gold clad silver alloy contacts in a twin contact structure which minimizes mechanical bouncing of contacts and increases reliability. In addition, each is available in 1-coil latching, 2-coil latching, or single side stable types. |
Applications: Measuring Equipment, Telecommunications, Data Processing, Alarm Equipment |
|