Product Description
Description: Power Relays • Rated Coil Voltage: 5 VDC • Contact Arrangement: 2C DPDT • Contact Current: 5 A • Operating Function : Single side stable • Terminal Type: PC board • Protective Construction: Dust Cover • Relay Shape : Slim type
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 5 VDC |
Contact Arrangement | 2C DPDT |
Contact Current | 5 A |
Operating Function | Single side stable |
Terminal Type | PC board |
Protective Construction | Dust Cover |
Relay Shape | Slim type |
Rated Operating Power | 360 mW |
Accessories | |
Operate Voltage (@20oC) | Max. 80% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 72 mA |
Resistance [±10%] (at 20°C) | 69.4 ? |
Max. Allowable Voltage | 135% V of rated coil voltage (at 50°C) |
Contact Shape | Twin |
Contact Resistance (Initial) | Max. 50 m? (by voltage drop 6 V DC 1 A) |
Contact Material | Au-clad AgNi type |
Contact Rating (Resistive Load) | 5 A 250 V AC, 5 A 30 V DC |
Max. Switching Power (Resistive Load) | 1,250 VA, 150 W |
Max. Switching Voltage | 250 V AC, 220 V DC |
Max. Switching Current | 5 A (AC, DC) |
Min. Switching Load (Reference Value) | 100 µA 1 V DC |
Insulation Resistance (Initial) | Min. 100 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact Sets | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 2,000 Vrms for 1 min (detection current: 10 mA) |
Operate Time (Initial) (At 20oC) | Max. 20 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 500x103 ope. 5 A 30 V DC Min. 100x103 ope. 5 A 250 V AC |
Series Features |
NC SERIES RELAYS |
Series Description: Panasonics NC Series Power Relays feature a high capacity of 5A 250VAC and 5A 30VDC (2 Form C) and 4A 250VAC and 5A 30VDC (4 Form C). These Relays are available with compact slim or flat design types. NC Series Relays are compatible with major safety standards, including UL, CSA, and Japanese Electrical Appliance and Material Control Law. The use of gold-clad twin bifurcated contacts provides stable contact resistance and ensures high contact reliability. NC Series Relays are also available with socket and terminal options for easier mounting. |
Applications: Electric Power Equipment; Industrial Equipment; Measuring Devices |
|