Product Description
This product has been Discontinued |
Description: Power Relays • Rated Coil Voltage: 9 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 8 A • Operating Function : Single side stable • Terminal Type: PC board • Protective Construction: Flux-resistant • TV Standards: TV-8 • Type Classification: Silent type
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 9 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 8 A |
Operating Function | Single side stable |
Terminal Type | PC board |
Protective Construction | Flux-resistant |
TV Standards | TV-8 |
Type Classification | Silent type |
Operate Voltage (@20oC) | Max. 80% V of Rated coil voltage (initial) |
Release Voltage (at20°C) | Min. 10% V of Rated coil voltage (initial) |
Rated Operating Current [±10%] (at 20°C) | 27.8 mA |
Resistance [±10%] (at 20°C) | 324 ? |
Rated Operating Power | 250 mW |
Max. Allowable Voltage (at 20°C 68°F) | 130% V of Rated coil voltage |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 8 A 277 V AC |
Max. Switching Power (Resistive Load) | 2,216 VA |
Max. Switching Voltage | 277 V AC |
Max. Switching Current | 8 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (At 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min. (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min. (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 15 ms (at rated coil voltage, without bounce) |
Release Time (Initial) (at 20°C) | Max. 5 ms (at rated coil voltage, without bounce, without diode) |
Hock Resistance (Functional) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical Life | Min. 1x106 ope. (at 180 times/min.) |
Conditions | Ambient temperature: -40 to +70°C Humidity: 5 to 85% R.H. (Avoid icing and condensation) |
Resistive Load | Min. 50,000 ope. 8 A 277 V AC (at 20°C, ON : OFF = 1.5 s : 1.5 s) |
Series Features |
LK-G SERIES RELAYS |
Series Description: 1mm .039inch contact gap 1 Form A 10A/16A power relays |
Applications: Audio visual equipment; HA equipment; Home appliances; Office equipment |
|