Product Description
Description: Power Relays • Rated Coil Voltage: 4.5 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 16 A • Operating Function : Single side stable • Terminal Type: PC board • Protective Construction: Flux-resistant • Relay Shape : Flat type • Coil Insulation Class: Class E insulation
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 4.5 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 16 A |
Operating Function | Single side stable |
Terminal Type | PC board |
Protective Construction | Flux-resistant |
Relay Shape | Flat type |
Coil Insulation Class | Class E insulation |
Rated Operating Power | 200 mW |
Operate Voltage (@20oC) | Max. 75% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 44.4 mA |
Resistance [±10%] (at 20°C) | 101 ? |
Max. Allowable Voltage (at 20°C 68°F) | 150% V of rated coil voltage |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Max. Switching Power (Resistive Load) | 2,770 VA, 300 W |
Contact Rating (Resistive Load) | 16 A 125 V AC, 10 A 277 V AC, 10 A 30 V DC |
Max. Switching Voltage | 277 V AC, 110 V DC (0.3 A) |
Max. Switching Current | 16 A (AC), 10 A (DC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 2,500 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 4,500 V |
Release Time (Initial) (at 20°C) | Max. 5 ms at rated coil voltage (without bounce, without diode) |
Operate Time (Initial) (At 20oC) | Max. 12 ms (4.5 to 48 VDC) at rated coil voltage (without bounce) |
Hock Resistance (Functional) | 200 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.6 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 2 mm) |
Mechanical Life | Min. 20x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [at 20°C, switching frequency: 20 times/min] Min. 100x103 ope. 10 A 125 V AC Min. 100x103 ope. 10 A 30 V DC Min. 50x103 ope. 10 A 277 V AC Min. 30x103 ope. 16 A 125 V AC |
Series Features |
JV-N SERIES RELAYS |
Series Description: 1 Form A 16 A, low profile : 10.9 mm power relays for heater control |
Applications: Home appliances |
|