Product Description
Description: Power Relays • Rated Coil Voltage: 100 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 30 A • Operating Function : Single side stable • Terminal Type: TM Type • Protective Construction: Dust Cover
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 100 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 30 A |
Operating Function | Single side stable |
Terminal Type | TM Type |
Protective Construction | Dust Cover |
Coil Type | DC type (DC coil) |
Rated Operating Power | 1,920 mW |
Accessories | |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 19 mA |
Resistance [±10%] (at 20°C) | 5,200 ? |
Max. Allowable Voltage | 110% V of rated coil voltage (at 55°C) |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 30 A 277 V AC |
Max. Switching Power (Resistive Load) | 8,310 VA |
Max. Switching Voltage | 277 V AC, 30 V DC |
Max. Switching Current | 30 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 30 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Mechanical Life | Min. 10x106 ope. (switching frequency: at 180 times/min) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Conditions | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC |
Dielectric Strength (Initial): Between Contact Sets | |
Insulation Distance | Min. 8 mm |
Contact Gap | Min. 3 mm (reference value) |
Series Features |
HE-N SERIES RELAYS |
Series Description: High Capacity. Low Power Consumption. Panasonic's HE-N Series General Power Relays feature high switching capacity of 120A @ 480VAC or 55A @ 800VAC in a 1 Form A (SPST-NO) contact arrangement. These Relays offer a compact size of 50mm x 40mm x 43mm which can be mounted on a PC Board without screw terminals for easier design and faster board assembly. HE-N Series General Power Relays also have a large contact gap of 3.6mm which is a requirement for solar inverter applications. These Relays are well suited for many energy management applications with low power consumption and only 400mW coil holding power. |
Applications: Inverter, Battery storage system, Stationary charging stand, Industrial equipment |
|