Product Description
Description: Power Relays • Rated Coil Voltage: 110 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 30 A • Operating Function : Single side stable • Terminal Type: Plug-in • Protective Construction: Dust Cover
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 110 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 30 A |
Operating Function | Single side stable |
Terminal Type | Plug-in |
Protective Construction | Dust Cover |
Coil Type | DC type (DC coil) |
Rated Operating Power | 1,920 mW |
Accessories | Terminals are available. |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 18 mA |
Resistance [±10%] (at 20°C) | 6,300 ? |
Max. Allowable Voltage | 110% V of rated coil voltage (at 55°C) |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 30 A 277 V AC |
Max. Switching Power (Resistive Load) | 8,310 VA |
Max. Switching Voltage | 277 V AC, 30 V DC |
Max. Switching Current | 30 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 2,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 30 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Mechanical Life | Min. 10x106 ope. (switching frequency: at 180 times/min) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Conditions | Ambient temperature: -50 to +55°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 200x103 ope. 30 A 250 V AC |
Dielectric Strength (Initial): Between Contact Sets | |
Insulation Distance | Min. 8 mm |
Contact Gap | Min. 3 mm (reference value) |
Series Features |
HE SERIES RELAYS |
Series Description: Panasonics HE Series Relays are characterized by their coil holding voltage, which can be reduced up to 30% V of the nominal coil voltage. This results in an operating power of approximately 170 mW, which contributes to equipment energy savings. The HE Series Relays are ideal for various applications such as photovoltaic power generation systems, uninterruptible power supplies, industrial equipment, and more. |
Applications: Office equipment; Industrial equipment; Home appliances |
|