Product Description
Description: Power Relays • Rated Coil Voltage: 5 VDC • Contact Arrangement: 1A+1B SPST-NO+SPST-NC • Contact Current: 5 A (AC, DC) • Operating Function : Single side stable • Terminal Type: PC Board • Protective Construction: Sealed
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 5 VDC |
Contact Arrangement | 1A+1B SPST-NO+SPST-NC |
Contact Current | 5 A (AC, DC) |
Operating Function | Single side stable |
Terminal Type | PC Board |
Protective Construction | Sealed |
Accessories | Sockets are available. |
Operate Voltage (@20oC) | Max. 80% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 60 mA |
Resistance [±10%] (at 20°C) | 83? |
Rated Operating Power | 300 mW |
Max. Allowable Voltage (at 20°C 68°F) | 130% V of rated coil voltage |
Contact Resistance (Initial) | Max. 30 m? (by voltage drop 6 V DC 1 A) |
Contact Material | Au-flashed AgSnO2 type |
Contact Rating (Resistive Load) | 5 A 250 V AC, 5 A 30 V DC |
Max. Switching Power (Resistive Load) | 1,250VA, 150W |
Max. Switching Voltage | 250 V AC, 125 V DC (0.2 A) |
Max. Switching Current | 5 A (AC, DC) |
Min. Switching Load (Reference Value) | 10 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 3,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 5,000 V |
Operate Time (Initial) (At 20oC) | Max. 10 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 5 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Dielectric Strength (Initial): Between Contact Sets | 2,000 Vrms for 1 min (detection current: 10 mA) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3.5 mm) |
Mechanical Life | Min. 50x106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +60°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 100x103 ope. 5 A 250 V AC Min. 100x103 ope. 5 A 30 V DC |
Set Voltage | |
Reset Voltage | |
Time (Initial) (at 20°C 68°F) (Initial) | |
Reset Time (Initial) (at20°C 68°F) | |
Contact Shape | Single |
Series Features |
DSP SERIES RELAYS |
Series Description: Panasonics DSP Series Polarized Power Relays are characterized for their high sensitivity, which allows for 190 mW and breakdown voltage which has been raised by keeping the coil and contacts separate. Three types of contact arrangements are offered for this series, 1a, 2a, and 1a1b. In addition, each is available in standard and reversed polarity types. The DSP Series Relays are ideal for various applications, including office and industrial electronic devices, terminal devices for information processing equipment, measuring instruments, and more. |
Applications: Electric power equipment, Measuring instruments, Industrial machines, OA equipment |
|