Product Description
Description: Power Relays • Rated Coil Voltage: 24 VDC • Contact Arrangement: 2A DPST-NO • Contact Current: 8 A • Operating Function : Single side stable • Terminal Type: PC board • Protective Construction: Sealed
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 24 VDC |
Contact Arrangement | 2A DPST-NO |
Contact Current | 8 A |
Operating Function | Single side stable |
Terminal Type | PC board |
Protective Construction | Sealed |
Insulation Distance | [Between contact and coil] Min. 8 mm (Clearance and Creepage) |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Set Voltage | |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Reset Voltage | |
Rated Operating Current [±10%] (at 20°C) | 8.3 mA |
Resistance [±10%] (at 20°C) | 2,880 ? |
Rated Operating Power | 200 mW |
Max. Allowable Voltage (at 20°C 68°F) | 130% V of rated coil voltage |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 30 m? (by voltage drop 6 V DC 1 A) |
Max. Switching Power (Resistive Load) | 2,000 VA (AC), 240 W (DC) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 8 A 250 V AC, 8 A 30 V DC |
Max. Switching Voltage | 250 V AC, 30 V DC |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 12,000 V |
Time (Initial) (at 20°C 68°F) (Initial) | |
Reset Time (Initial) (at20°C 68°F) | |
Operate Time (Initial) (At 20oC) | Max. 10 ms at rated coil voltage (without bounce) |
Dielectric Strength (Initial): Between Contact Sets | 4,000 Vrms for 1 min (detection current: 10 mA) |
Release Time (Initial) (at 20°C) | Max. 5 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 196 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 2 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
Mechanical Life | Min. 10x106 ope. (switching frequency: at 300 times/min) |
Conditions | Ambient temperature: -40 to +70°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 50x103 ope. 8 A 30 V DC |
Series Features |
DE SERIES RELAYS |
Series Description: Panasonics DE Series Polarized Power Relays are distinguished by their compact body, providing board space, and low nominal operating power at 200 mW, single side stable, 2 coil latching. These DE Series Relays are ideal for various applications, including OA and FA equipment, automatic meter readings, and temperature controllers. |
Applications: Temperature controller, Automatic meter reading system, OA equipment, Industrial equipment, Lighting control system |
|