Description: Power Relays • Rated Coil Voltage: 60 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 6 A • Operating Function : Single side stable • Terminal Type: PC Board • Protective Construction: Sealed • Relay Shape : Slim type • Contact Material: AgNi type
| Product Information | Resources | 
| 
 | 
 | 
| Specifications | 
| Product Attribute | Attribute Value | 
| Rated Coil Voltage | 60 VDC | 
| Contact Arrangement | 1A SPST-NO | 
| Contact Current | 6 A | 
| Operating Function | Single side stable | 
| Terminal Type | PC Board | 
| Protective Construction | Sealed | 
| Relay Shape | Slim type | 
| Contact Material | AgNi type | 
| Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) | 
| Release Voltage (at20°C) | Min. 5% V of rated coil voltage (Initial) | 
| Rated Operating Current [±10%] (at 20°C) | 2.9 mA | 
| Resistance [±10%] (at 20°C) | 20,570 ? | 
| Rated Operating Power | 175 mW | 
| Max. Allowable Voltage (at 20°C 68°F) | 120% V of rated coil voltage | 
| Contact Shape | Single | 
| Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) | 
| Contact Rating (Resistive Load) | 6 A 250 V AC | 
| Max. Switching Power (Resistive Load) | 1,500 VA | 
| Max. Switching Voltage | 250 V AC | 
| Min. Switching Load (Reference Value) | 100 mA 5 V DC | 
| Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) | 
| Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) | 
| Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min (detection current: 10 mA) | 
| Surge Withstand Voltage (Initial): Between Contact and Coil | 6,000 V | 
| Operate Time (Initial) (At 20oC) | Max. 8 ms at rated coil voltage (without bounce) | 
| Release Time (Initial) (at 20°C) | Max. 4 ms at rated coil voltage (without bounce, without diode) | 
| Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) | 
| Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 11 ms) | 
| Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1 mm, detection time: 10 µs) | 
| Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) | 
| Mechanical Life | Min. 5x106 ope. (switching frequency: at 180 times/min) | 
| Conditions | Ambient temperature: -40 to +85°C (Allowable temperature is from -40 to +60°C at our standard packing condition.) Humidity: 5 to 85% RH (Avoid icing and condensation) | 
| Resistive Load | [switching frequency: 6 times/min] Min. 50x103 ope. 6 A 250 V AC | 
| Series Features | 
| PF SERIES RELAYS | 
| Series Description: Panasonics PF Series Relays have been developed to comply with standards required for Programmable Logic Controllers (PLC) for production facilities, including reinforced insulation to satisfy EN/IEC 61810-1 standards. The PF Series Relay products can switch a 6A at 250 V AC and AC15 and DC13 inductive loads. These Relays are available in 1 Form A or 1 Form C contact arrangement with a slim footprint to allow for high-density mounting. The PF Series features a high 4000V breakdown voltage and 6000V surge voltage to protect controllers against surges and noise. | 
| Applications: Industrial Equipment And Office Equipment, Measuring Equipment And Test Equipment, Programmable Controller, Household Appliances For Europe | 
| 
 | 
 
             
                         
             
   RoHS Compliant
  RoHS Compliant