Product Description
Description: Power Relays • Rated Coil Voltage: 5 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 16 A • Operating Function : Single side stable • Terminal Type: PC board terminal • Protective Construction: Flux-resistant • Coil Insulation Class: Class F insulation • Relay Shape : Low profile type
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 5 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 16 A |
Operating Function | Single side stable |
Terminal Type | PC board terminal |
Protective Construction | Flux-resistant |
Coil Insulation Class | Class F insulation |
Relay Shape | Low profile type |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 80 mA |
Resistance [±10%] (at 20°C) | 63 ? |
Rated Operating Power | 400 mW |
Max. Allowable Voltage | 130% V of rated coil voltage (at 105°C) |
Contact Shape | Single |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 16 A 250 V AC |
Max. Switching Power (Resistive Load) | 4,000 VA |
Max. Switching Voltage | 440 V AC |
Max. Switching Current | 16 A |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 15 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 5 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical Life | Min. 10x106 ope. |
Conditions | Ambient temperature: -40 to +105°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [at 20°C, switching frequency: 20 times/min] Min. 100x103 ope. 16 A 250 V AC |
Series Features |
LZ SERIES RELAYS |
Series Description: Low profile: 15.7 mm, 1 Form A/1 Form C 16 A, Power relay |
Applications: Household electrical appliances; Office equipment; Industrial equipment |
|