Product Description
Description: Power Relays • Rated Coil Voltage: 24 VDC • Contact Arrangement: 1A SPST-NO • Contact Current: 31 A • Operating Function : Single side stable • Terminal Type: PC Board • Protective Construction: Flux-resistant • Contact Type: High capacity type • Contact Gap: 1.5 mm • Coil Insulation Class: Class F insulation
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 24 VDC |
Contact Arrangement | 1A SPST-NO |
Contact Current | 31 A |
Operating Function | Single side stable |
Terminal Type | PC Board |
Protective Construction | Flux-resistant |
Contact Type | High capacity type |
Contact Gap | 1.5 mm |
Coil Insulation Class | Class F insulation |
Insulation Distance | [Between contact and coil] Clearance: Min. 6.5 mm, Creepage: Min. 9.5 mm |
Operate Voltage (@20oC) | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 59 mA |
Resistance [±10%] (at 20°C) | 410 ? |
Rated Operating Power | 1,400 mW |
Max. Allowable Voltage (at 20°C 68°F) | 120% V of rated coil voltage |
Contact Shape | Single |
Contact Material | AgSnO2 type |
Contact Rating (Resistive Load) | 31 A 250 V AC |
Max. Switching Power (Resistive Load) | 7,750 VA |
Max. Switching Voltage | 250 V AC |
Max. Switching Current | 31 A (AC) |
Min. Switching Load (Reference Value) | 100 mA 5 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric Strength (Initial): Between Open Contacts | 2,500 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 6,000 V |
Coil Holding Voltage | 35 to 120% V (contact carrying current: 31 A, at 20°C) 40 to 80% V (contact carrying current: 31 A, at 85°C) |
Operate Time (Initial) (At 20oC) | Max. 20 ms at rated coil voltage (without bounce) |
Release Time (Initial) (at 20°C) | Max. 10 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Hock Resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical Life | Min. 106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +60°C (When rated coil voltage applied) Ambient temperature: -40 to +85°C (When coil holding voltage is 45 to 80% V of rated coil voltage) Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | - |
Destructive | [switching frequency ON : OFF = 0.1 s : 10 s] Min. 30x103 ope. 31 A 250 V AC (cos? = 0.8) |
Over Load | [switching frequency ON : OFF = 0.1 s : 10 s] Min. 50 ope. 47 A 250 V AC (cos? = 0.8) |
Contact Resistance (Initial) | Max. 100 m? (by voltage drop 6 V DC 1 A) |
Series Features |
LF-G SERIES RELAYS |
Series Description: Panasonics LF-G Series Relays are non-polarized 1 Form A power Relays that can switch up to 33 amps at 250 volts AC. This series is offered with a 1.5 or 1.8-millimeter contact gap and comply with photovoltaic standards, making them ideal for AC line switching in solar applications as well as UPS, microwave ovens, battery charge, and discharge systems. To save energy, designer engineers can reduce the coil holding voltage to 35% of the nominal coil voltage, dropping the operating power to 170 milliwatts. These Relays have a compact size that allows for smaller, higher-density designs, and feature excellent creepage, clearance, and breakdown voltage to ensure safe operation. |
Applications: Photovoltaic power generation systems (Solar inverter), Uninterruptible Power Supplies (UPS), Home appliances, Office equipment |
|