Product Description
Description: Power Relays • Rated Coil Voltage: 12 VDC • Contact Arrangement: 1A+1B SPST-NO+SPST-NC • Contact Current: 8 A • Operating Function : Single side stable • Terminal Type: PC board • Protective Construction: Sealed
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Rated Coil Voltage | 12 VDC |
Contact Arrangement | 1A+1B SPST-NO+SPST-NC |
Contact Current | 8 A |
Operating Function | Single side stable |
Terminal Type | PC board |
Protective Construction | Sealed |
Accessories | Sockets are available. |
Rated Operating Power | 200 mW |
Pick-Up Voltage | 70%V or less of rated coil voltage (Initial) |
Drop-Out Voltage | 10%V or more of rated coil voltage (Initial) |
Max. Switching Voltage | 250 V AC, 125 V DC (0.2 A) |
Max. Switching Current | 8 A (AC, DC) |
Min. Switching Load (Reference Value) | 10 mA 5 V DC |
Contact Material | Au-flashed AgSnO2 type |
Mechanical Life | Min. 50x106 ope. (switching frequency: at 300 times/min) |
Electrical Life | Min. 1x105 |
Dielectric Strength (Initial): Between Open Contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric Strength (Initial): Between Contact and Coil | 4,000 Vrms for 1 min (detection current: 10 mA) |
Ambient Temperature | Ambient temperature: 40 to +70°C Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) |
Set Voltage | Max. 70% V of rated coil voltage (Initial) |
Release Voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated Operating Current [±10%] (at 20°C) | 16.6 mA |
Resistance [±10%] (at 20°C) | 720 ? |
Max. Allowable Voltage (at 20°C 68°F) | 130% V of rated coil voltage |
Contact Resistance (Initial) | Max. 30 m? (by voltage drop 6 V DC 1 A) |
Contact Rating (Resistive Load) | 8 A 250 V AC, 8 A 30 V DC |
Insulation Resistance (Initial) | Min. 1,000 M? (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Surge Withstand Voltage (Initial): Between Contact and Coil | 10,000 V |
Operate Time (Initial) (At 20oC) | Max. 10 ms at rated coil voltage (without bounce) |
Hock Resistance (Functional) | 98 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 µs) |
Release Time (Initial) (at 20°C) | Max. 8 ms at rated coil voltage (without bounce, without diode) |
Hock Resistance (Destructive) | 980 m/s2 (half-sine shock pulse: 6 ms) |
Vibration Resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, detection time: 10 µs) |
Vibration Resistance (Destructive) | 10 to 55 Hz (at double amplitude of 3 mm) |
Conditions | Ambient temperature: -40 to +70°C Humidity: 5 to 85% RH (Avoid icing and condensation) |
Resistive Load | [switching frequency: 20 times/min] Min. 100x103 ope. 8 A 250 V AC Min. 100x103 ope. 8 A 30 V DC |
Time (Initial) (at 20°C 68°F) (Initial) | - |
Reset Time (Initial) (at20°C 68°F) | - |
Dielectric Strength (Initial): Between Contact Sets | 4,000 Vrms for 1 min |
Max. Switching Power (Resistive Load) | 2,000 VA, 240 W |
Series Features |
DY SERIES RELAYS |
Series Description: Panasonics DY Series Polarized Power Relays are characterized by a high capacity of 1 Form A (10A 250V AC), 1 Form A 1 Form B (8A 250V AC), and long insulation distance generated by reinforced insulation with 6 mm distance between input and output. The DY Series Relays are ideal for various applications, including control for industrial machines, output relays for temperature, measuring and security equipment. |
Applications: Control for machine tools and robots; Output for temperature controller, PLC, timers and sensors; Measuring equipment; Security equipment |
|