Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | OptiFuse |
| Manufacturer Product Number | MOCBP4-PM-5A |
| Description | Automotive Circuit Breaker; 5A; 14 VDC; Type II - Modified Reset |
| Datasheet | Download Datasheet |
The OptiFuse MOCBP4-PM-5A is a 5 A mini blade automotive circuit breaker with modified reset (SAE J553 Type II), staying tripped while the fault and power remain and resetting once power is removed, rated 14 VDC.
It plugs into a mini blade fuse holder.
Its body is tan thermoplastic (UL rated 94V-0).
It interrupts 150 A @ 14 VDC. It operates from -40 to +85 °C.
Tested to SAE J553 Type II.
Size: 0.50 x 0.25 x 1.38 in (L x W x H).
| Category | |
| Manufacturer | OptiFuse |
| Model | MOCBP4-PM |
| Current Rating (A) | 5 |
| Voltage Rating - DC | 14 VDC |
| Reset Type | Type II - Modified Reset |
| Breaker Style | Mini Blade |
| Mounting Type | Plugs into a mini blade fuse holder |
| Terminal Type | Blade |
| Terminal Material | Tin plated Copper Alloy |
| Interrupting Rating | 150 A @ 14 VDC |
| Operating Temperature (°C) | -40 to +85 |
| Standards | SAE J553 Type II |
| Body Color | Tan |
| Body Material | Thermoplastic (UL Rated 94V-0) |
| Number of Poles | 1 |
| Dimensions | 0.50 x 0.25 x 1.38 in |