Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | OptiFuse |
| Model | CBW57 |
| Manufacturer Product Number | CBW57-SS-11A-W |
| Description | Thermal Circuit Breaker; 11 A; 125/250 VAC; 32/50 VDC; Straight, 0.46 in (11.8 mm) |
| Datasheet | Download Datasheet |
The OptiFuse CBW57-SS-11A-W is an 11 A low profile thermal circuit breaker, push to reset, rated 125/250 VAC and 32/50 VDC.
It mounts through the panel on a 8 mm high plastic Panel bushing.
Its terminals are straight 0.250 in (6.35 mm) quick connect tabs, 0.46 in (11.8 mm) long; the reset button is white.
It interrupts 1000 A @ 125/250 VAC (3-30 A), 400 A @ 125/250 VAC (3-20 A), 300 A @ 50 VDC (3-30 A). Trip times at 25 °C, as a share of the rating: 100%: no trip; 150%: trips within 1 hour; 200%: 5-30 s; 300%: 1.5-5 s. It operates from -10 to +60 °C.
It is ignition protected to SAE J1171 and UL 1500, for marine engine compartments. Approvals: cURus (UR) 125/250 VAC, 50 VDC, CCC 125/250 VAC, TÜV 125/250 VAC, 32 VDC, VDE 125/250 VAC, RoHS Compliant.
Typical uses: supplementary overcurrent protection for equipment on utility power or high-current AC/DC circuits: industrial equipment, motor homes and marine.
| Category | |
| Manufacturer | OptiFuse |