Product Description
Description: Start Bars • Features: Start bar with digital counter and timer • Physical Dimensions: 50 cm x 10 cm x 6 cm (20? x 3.75? x 2.15?) • Mounting Holes: 2 vertical, tapped 1/4-20 threads; 2 horizontal, 1/4? diameter thru-hole • Power Supply: 115 VAC or 220 VAC (factory configured) • Power Consumption: Input X1 • NPN (sinking) type, 24VDC, 15mA. Typically used for Hold function. (p/n TB-2SRNPN); PNP (sourcing) type 24VDC, 15mA. (p/n TB-2SRPNP): PNP (sourcing) type, 24VDC, 15mA. Typically used for Reset function. • Input X3: PNP (sourcing) type, 24VDC, 15mA. Typically used for Reset function. • Output X2: 24 VDC, 0.1 Amps; 2 positive guided relay contacts in series, Life: 10 million cycles (mechanical)
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Features | Start bar with digital counter and timer |
Physical Dimensions | 50 cm x 10 cm x 6 cm (20? x 3.75? x 2.15?) |
Weight | 3 kg (6.5 lbs.) |
Mounting Holes | 2 vertical, tapped 1/4-20 threads; 2 horizontal, 1/4? diameter thru-hole |
Power Supply | 115 VAC or 220 VAC (factory configured) |
Power Consumption | 5 watts standby, 8 watts output energized |
Input X1 | NPN (sinking) type, 24VDC, 15mA. Typically used for Hold function. (p/n TB-2SRNPN); PNP (sourcing) type 24VDC, 15mA. (p/n TB-2SRPNP) |
Input X3 | PNP (sourcing) type, 24VDC, 15mA. Typically used for Reset function. |
Output X2 | 24 VDC, 0.1 Amps; 2 positive guided relay contacts in series, Life: 10 million cycles (mechanical) |
Concurrency Timer | 0.5 sec. (factory setting) |
Environmental | 0° 60° C (32 140° F) ambient temp. |
Origin | Made in USA |
Start Switches | Electronic infrared photo sensors approximately 80 millisecond response time |
Series Features |
Model TB-2SR Start Bar |
Series Description: The Nolatron TB-2SR machine start bar is a complete OSHA compliant ergonomic two hand starting system. It increases productivity while operator fatigue and stress are decreased. It includes a cast aluminum enclosure, guarded hand sensors and an anti-tiedown control with front panel indicator lights. When properly installed, the TB-2SR start bar meets OSHA requirements of section 1910.217(6) which covers two-hand controls. |
Series Operation: The start bar has several operation modes. They are defined by setting options in the Setup Menu. Momentary Output The output will remain ON until one or both start switches are released. Maintained Output After the external Hold switch is closed, the output will remain ON after the start switches are released. The output will stay on until the external Reset switch is closed or if the external Hold switch is opened. Timed Output The output will remain ON until one or both start switches are released, or until the dwell timer reaches zero. Timing starts when the output turns on. Maintained Timed Output After the external Hold switch is closed, the output will remain ON after the start switches are released. The output will stay on until the dwell timer reaches zero or until the external Hold switch is opened. Timing starts when the output turns on. Delayed Timed Output The output will remain ON until one or both start switches are released, or until the dwell timer reaches zero. Timing starts when external the Hold switch is closed. Maintained Delayed Timed Output After the external Hold switch is closed, the output will remain ON after the start switches are released. The output will stay on until the dwell timer reaches zero or the external Hold switch is opened. Timing starts when external Hold switch is closed. Part-in-Place Mode The bar will not respond to the start switches until the external Reset switch is closed. In this mode, the external Reset switch cannot be used to end the machine cycle, and the Hold feature will only work with a timed output. |
|