Product Description
Description: Anti-Tiedown Controls • Physical Dimensions: 88 mm (3.5?) High, 60 mm (2.625?) Wide, 45 mm (1.75?) Deep • Operating Voltage: 115 VAC, 50/60Hz. (12 and 24 V AC/DC also available) • Power Consumption: 0.3 Watts (pin 3 energized) / 6 Watts (pin 2 energized) • Output Ratings : 8 Amps@115 VAC (switching), 6 Amps@115 VAC (continuous) • Output time: 0.2 1.0 second, factory set at 0.5 seconds • Wiring Connection Standard: plug-in 11 pin
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Physical Dimensions | 88 mm (3.5?) High, 60 mm (2.625?) Wide, 45 mm (1.75?) Deep |
Operating Voltage | 115 VAC, 50/60Hz. (12 and 24 V AC/DC also available) |
Power Consumption | 0.3 Watts (pin 3 energized) / 6 Watts (pin 2 energized) |
Output Ratings | 8 Amps@115 VAC (switching), 6 Amps@115 VAC (continuous) |
Output time | 0.2 1.0 second, factory set at 0.5 seconds |
Wiring Connection Standard | plug-in 11 pin |
Series Features |
Model 3380-T Two-Hand Machine Control Anti-Tiedown Monitor |
Series Description: Nolatrons anti-tiedown controls are used in conjunction with two start switches to help protect machinery operators. The 3380 series helps to comply with OSHA, which requires a machine operator to have both hands on the start switches in order to start a machine cycle. This minimizes the possibility of the operator starting the machine while one hand is in the work area. Both start switches must be activated within a fixed time interval to energize the output. This prevents an operator from tying down one of the switches while continuing to operate the machine. The 3380 uses redundant positive guided output contacts which are cross-checked before every machine cycle. A single component failure will cause the control to shut down in a safe mode. |
Series Operation: Momentary Output In order for a machine cycle to begin, both start switches must be pressed within .5 sec. (this time is internally adjustable). As long as the start switches remain activated, the output will remain energized for a time of .5 seconds. The output time is internally adjustable with a range of .2 to 1 second. Both start switches must be released before another machine cycle can be started. If either start switch is tied down, the cycle can not be repeated. |
|