Product Description
Description: Signal Relay • Coil Voltage: 5 VDC • Contact Configuration: 2C DPDT • Current: 1 Amp • Function: Single Side Stable • Mounting: PC Board • Option: Low Power consumption, Minimum footprint type
Product Information | | Resources |
Manufacturer | NEC - World Products | Product Category | Relay | Product Sub Category | Signal Relay | Series | UD2 Series |
| | |
Product Attribute
| Attribute Value
|
Coil Voltage | 5 VDC |
Contact Configuration | 2C DPDT |
Current | 1 Amp |
Function | Single Side Stable |
Mounting | PC Board |
Option | Low Power consumption, Minimum footprint type |
Contact Material | Silver alloy with gold alloy overlay |
Minimum Contact Ratings | 10 m VDC, 10?A |
Initial Contact Resistance | 100 m ? max. (initial) |
Operate Time [Set Time] (Excluding bounce) | Approx. 2 ms [2ms] |
Release Time [Reset Time] (Excluding bounce) | Approx. 1 ms [2ms] (Without diode) |
Insulation Resistance | 1000 M ohms at 500 VDC |
Withstanding Voltage | Between open contacts: 1000 VAC (for one minute) 1500 V surge (10x160 ?s) Between adjacent contact: 1000 VAC (for one minute) 1500 V surge (10x160 ?s) Between coil and contacts: 1500 VAC (for one minute) , 2500 V surge (2x10 ?s) |
Shock Resistance | 735 m/s2 (75G) (misoperation) 980 m/s2 (100G) (destructive failure) |
Vibration Resistance | 10 to 55 Hz, double amplitude 3 mm(196 m/s2) (misoperation) 10 to 55 Hz, double amplitude 5 mm(294 m/s2) (destructive failure) |
Ambient Temperature | -40 to +85 °C -40 to +70 °C(Low Power consumption type) |
Coil Temperature Rise | 13 °C / 100mW, 18 °C / 140mW, 25 °C |
UC2/UD2 Series |
Series Description: NEXEM UC2/UD2 relay is a new generation minature signal relay, super-comact and flat. |
Applications: Electronic switching systems, PBX, Terminal equipment, Telephone systems |
- Small mounting size of flat package for dense mounting.
- Telcordia (2500 V) and FCC (1500 V) surge capacity
- IEC62368-1/EN62368-1 spacing (Basic insulation class on 200 V working voltage)
- Low power consumption (100-140 mW)
- Moisture Barrier Bag (MBB) packaged UD2 relays meet moisture sensibility level (MSL) of IPC/JEDEC-STD-02, 075.
|