Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Mersen / Ferraz Shawmut |
| Manufacturer Product Number | STZ240S45BQ |
| Description | Surge Protection Device; 240/120 V AC; 240/120 V Split Phase |
| Datasheet | Download Datasheet |
The Mersen / Ferraz Shawmut STZ240S45BQ is a UL Type 1 surge protection device for 240/120 V AC 240/120 v split phase systems: field-replaceable module.
A UL Type 1 SPD is permanently connected and may be installed on the line side of the service disconnect as well as the load side.
Nominal discharge current (In): 20 kA (8x20 µs). Maximum discharge current (Imax): 450 kA. Short circuit current rating (SCCR): 200 kA.
Status indication: lED status indicator: green = 67 to 100% life, yellow = 34 to 66% life, red = 0 to 33% life; LED phase loss indication. Up to -50 dB from 10 kHz to 100 MHz. Monitoring: audible alarm with silence button; phase loss indication; surge counter. Back-up fuse: Not required (does not require additional overcurrent protection). Response time Less than 1 nanosecond (one per phase).
Connection: 8 AWG - 1/0 phase and neutral; 8 AWG - 2/0 ground (see installation instructions for details by option and lug torque). Housing: uL94-5VA. It operates from -35 °C to +85 °C (-31 °F to +185 °F), operating and storage °C. Size: 8.31 in (211 mm) W x 8.47 in (215.1 mm) H x 2.98 in (75.6 mm) D; 8x dia. 0.25 in (6.4 mm) mounting holes.
Approvals: UL Listed, CSA Certified, RoHS.
| Category | |
| Manufacturer | Mersen / Ferraz Shawmut |
| Model | STZ |
| SPD Type | UL 1449 Type 1 (panel mount SPD for UL 1449 Type 1 and 2 applications) |
| Product Form | Field-replaceable module |
| Configuration | 240/120 V Split Phase |
| Nominal System Voltage | 240/120 V AC |
| Nominal Discharge Current | 20 kA (8x20 µs) |
| Maximum Discharge Current | 450 kA |
| Short Circuit Current Rating | 200 kA |
| Network Systems | 50 Hz or 60 Hz |
| Status Indication | LED status indicator: green = 67 to 100% life, yellow = 34 to 66% life, red = 0 to 33% life; LED phase loss indication |
| Remote Contact | Form C dry contacts |
| Thermal Protection | Yes (Mersen TPMOV technology) |
| EMI/RFI Filtering | Up to -50 dB from 10 kHz to 100 MHz |
| Alarms / Monitoring | Audible alarm with silence button; phase loss indication; surge counter |
| Back-up Fuse | Not required (does not require additional overcurrent protection) |
| Response Time | Less than 1 nanosecond (one per phase) |
| Connection | 8 AWG - 1/0 phase and neutral; 8 AWG - 2/0 ground (see installation instructions for details by option and lug torque) |
| Housing Material | UL94-5VA |
| Operating Temperature (°C) | -35 °C to +85 °C (-31 °F to +185 °F), operating and storage |
| Dimensions | 8.31 in (211 mm) W x 8.47 in (215.1 mm) H x 2.98 in (75.6 mm) D; 8x dia. 0.25 in (6.4 mm) mounting holes |
| Approvals | UL Listed, CSA Certified, RoHS |