Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Mersen / Ferraz Shawmut |
| Manufacturer Product Number | STXR600D05A |
| Description | Surge Protection Device; 600 V AC; 3-phase delta; L-G 690 V AC; L-L 840 V AC |
| Datasheet | Download Datasheet |
The Mersen / Ferraz Shawmut STXR600D05A is a UL Type 1 surge protection device for 600 V AC 3-phase delta systems: panel-mount enclosed unit.
A UL Type 1 SPD is permanently connected and may be installed on the line side of the service disconnect as well as the load side.
Maximum continuous operating voltage (MCOV / Uc): L-G 690 V AC; L-L 840 V AC. Voltage protection rating (UL VPR): L-G 2000 V AC; L-L 2500 V AC. Nominal discharge current (In): 20 kA. Maximum discharge current (Imax): 50 kA per phase and per mode. Short circuit current rating (SCCR): 200 kA. Modes of protection: L-G, L-L, for 50 Hz or 60 Hz networks.
Status indication: lED: green = functional, out = replace. Monitoring: audible alarm (sounds when any protection is lost); remote contact 125 V AC 1 A resistive / 30 V DC 2 A general purpose; pre-wired 36 in 18 AWG (red = NC, gray = common, blue = NO. Response time Less than 1 ns (one per phase).
Mounting: fits 3/4 in knockout (3/4 NPSM hub with lock nut); optional STXRMBK bracket for surface mount. Connection: Pre-wired 36 in (1 m) 10 AWG leads. Protection: NEMA 4X non-metallic enclosure. Housing: uL94-5VA. It operates from -40 to +85 °C (-40 to +185 °F), operating and storage; humidity 0 to 95% non-condensing °C. Size: 3.35 x 3.35 in face; 3.12 in deep plus 0.88 in hub; 36 in leads.
Approvals: UL Listed; CSA; RoHS.
| Category | |
| Manufacturer | Mersen / Ferraz Shawmut |
| Model | STXR |
| SPD Type | UL 1449 5th Edition Type 1 SPD; for Type 1 and Type 2 applications |
| Product Form | Panel-mount enclosed unit |
| Configuration | 3-phase delta |
| Nominal System Voltage | 600 V AC |
| Max Continuous Operating Voltage | L-G 690 V AC; L-L 840 V AC |
| Voltage Protection Rating | L-G 2000 V AC; L-L 2500 V AC |
| Nominal Discharge Current | 20 kA |
| Maximum Discharge Current | 50 kA per phase and per mode |
| Short Circuit Current Rating | 200 kA |
| Modes of Protection | L-G, L-L |
| Network Systems | 50 Hz or 60 Hz |
| Status Indication | LED: green = functional, out = replace |
| Remote Contact | Form C dry contact |
| Thermal Protection | Yes (TPMOV; no additional overcurrent protection needed) |
| Alarms / Monitoring | Audible alarm (sounds when any protection is lost); remote contact 125 V AC 1 A resistive / 30 V DC 2 A general purpose; pre-wired 36 in 18 AWG (red = NC, gray = common, blue = NO |
| Response Time | Less than 1 ns (one per phase) |
| Connection | Pre-wired 36 in (1 m) 10 AWG leads |
| Mounting | Fits 3/4 in knockout (3/4 NPSM hub with lock nut); optional STXRMBK bracket for surface mount |
| Degree of Protection | NEMA 4X non-metallic enclosure |
| Housing Material | UL94-5VA |
| Operating Temperature (°C) | -40 to +85 °C (-40 to +185 °F), operating and storage; humidity 0 to 95% non-condensing |
| Dimensions | 3.35 x 3.35 in face; 3.12 in deep plus 0.88 in hub; 36 in leads |
| Approvals | UL Listed; CSA; RoHS |