Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Macromatic |
| Manufacturer Product Number | THS-1134A-36T |
| Description | Time Delay Relay; 10...1,000 s; Watchdog; 24-240V AC; 1-Pin Trigger; 1A SPST-NO |
| Datasheet | Download Datasheet |
The Macromatic THS-1134A-36T is a time delay relay with 1A SPST-NO output and rated 1 A continuous, 10 A inrush at 65 °C, pilot duty, driven by a 24-240V AC input.
It is adjustable from 10 to 1,000 s and set by an onboard knob.
It is a Watchdog timer.
Upon application of control voltage, the time delay relay is ready to accept a trigger. When the trigger is applied, the output is energized and the time delay (t) begins. At the end of the time delay (t), the output is de-energized unless the trigger is removed and re-applied prior to time out (before time delay (t) elapses). Continuous cycling of the trigger at a rate faster than the time delay (t) will cause the output to remain energized indefinitely.
It is started by a control switch.
Build option: control switch common to pin 2 (single-pin trigger).
It has Surface Mounting and 0.250" (6.3mm) quick-connect terminals.
| Category | |
| Manufacturer | Macromatic |
| Model | THS-1 |
| Output Technology | Solid State |
| Timing Function | Watchdog |
| Delay Time | 10...1,000 s |
| Timing Adjustment Method | Onboard knob |
| Options | Control switch common to pin 2 (single-pin trigger) |
| Timing Initiate Method | Control Switch |
| Contact Configuration | 1A SPST-NO |
| Output Rating | 1 A continuous, 10 A inrush at 65 °C, pilot duty |
| Input Voltage | 24-240V AC |
| Termination Style | Quick Connect - 0.250" (6.3mm) |
| Mounting Type | Surface Mount |
| Operating Temperature | -28...+65 °C (-40...+85 °C) |
| Approvals | UL Recognized (E236146) |
| Setting Accuracy (%) | Maximum setting +5%/-0%, minimum setting +0%/-50% |
| Repeatability (%) | +0.1% or +0.04 s, whichever is greater, at constant voltage and temperature |
| Start-Up Time | 0.05 s |
| Maintain Function Time | 0.01 s |
| Input Operating Range | +10%/-15% of nominal, AC at 50/60 Hz and DC |
| Rated Power | 1 VA |