Product Description
This product has been Discontinued |
Description: Time Delay Relay • Non-Programmable • Type:Single Knob Unit • Function: Interval On • Input Voltage: 240 VAC • Timing Range: 1.8 - 180 min • Mounting : Plug-in 8 Pin Octal • Contact Configuration: DPDT
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage | 240V AC |
Timing Range | 1.8-180 minutes |
Mounting | 8 PIN OCTAL |
Contact Configuration | 2C DPDT |
Output Current | 10 Amps |
Voltage Tolerance | AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. |
Load (Burden) | Maximum of 2 VA for all voltages |
Setting Accuracy | Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% Fixed Time Delay: +2% or 50ms, whichever is greater |
Repeat Accuracy (constant voltage and temperature) | +0.1% or + 0.04 seconds, whichever is greater |
Reset Time | Input Voltage (All Functions) 0.100 Seconds Triggered Functions only 0.04 Seconds |
Start-up Time | (Time from when power is applied until unit is timing) 0.05 Seconds |
Maintain Function Time | (Time unit continues to operate after power is removed) 0.01 Seconds for all units |
Temperature: Operating | -28o to 65oC (-18o to 149oF) Storage: -40o to 85oC (-40o to 185oF) |
Output Contacts | (All TR-5 Series Products except TR-506 & TR-546) DPDT 10A @ 240V AC/30V DC, 1/2HP @ 120/240V AC (N.O.), 1/3HP @ 120/240V AC (N.C.) B300 & R300; AC15 & DC13 (TR-506 & TR-546) DPDT 10A @ 240V AC; 8A @ 28V DC, 1/2 HP @ 240V AC, 1/4HP @ 120V AC B300 & R300 |
Life | Mechanical: 10,000,000 operations (2,000,000 operations on TR-506 & TR-546 Series only) Full Load: 100,000 operations |
Triggering Off Delay, Single Shot or Watchdog Units | Timing sequence must be initiated only after input voltage is ap- plied to unit. Minimum required trigger switch closure time is 0.05 seconds. |
IMPORTANT FOR TR-506 & TR-546 SERIES ONLY | These relays are shipped from the factory in the OFF state. A shock to the relay during shipping or installation may cause it to change to the ON state. It is recommended that input voltage be applied to the product for at least 0.1 second and removed to cycle the unit to the OFF state prior to use in the application. Please note that it will take as long as the OFF Delay setting to reset the unit once input voltage has been removed. |
Series Features |
TR-5 Series Standard |
Series Description: TR-5 Non-Programmable plug-in time delay relays are flexible and reliable. The most common timing functions are available in all standard input voltages. Each product is offered with a choice of time delay adjustment: on-board adjustable with a single timing range; fixed time delay; or remote adjustable. All dual-time functions such as repeat cycle or delayed interval have an option for independently selectable and adjustable ON & OFF times for ultimate flexibility. These products utilize industry-standard 8 & 11 pin octal sockets, and have 10A DPDT output contacts (selected functions that are normally offered with 11 pin DPDT output are also available in 8 pin SPDT versions). |
|