Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Macromatic |
| Manufacturer Product Number | TD-88164 |
| Description | TDR; 0.05 s...10,230 h; Multi-Function; 48V AC/DC; 1C SPDT |
| Datasheet | Download Datasheet |
The Macromatic TD-88164 is a time delay relay with 1C SPDT output and rated 10 A at 240 V AC, 10 A at 30 V DC, driven by a 48V AC/DC input.
It is adjustable from 0.05 s to 10,230 h and set by two 10-position DIP switches, function and time.
It offers On Delay, Interval On, Flasher (OFF 1st), Flasher (ON 1st), Off Delay, Single Shot, Watchdog, Single Shot (Trailing Edge), Repeat Cycle (OFF 1st), Repeat Cycle (ON 1st), Delayed Interval, Triggered Delayed Interval, On/Off Delay, Single Shot-Flasher, On Delay/Flasher, Triggered On Delay.
It is started by applying the supply or a control switch, depending on the function.
It has Socketable mounting and Plug In terminals.
| Category | |
| Manufacturer | Macromatic |
| Model | TD-881 |
| Output Technology | Electromechanical Relay |
| Timing Function | Multi-Function |
| Delay Time | 0.05 s...10,230 h |
| Timing Adjustment Method | Two 10-position DIP switches, function and time |
| Timing Initiate Method | Input Voltage or Control Switch, by function |
| Available Timing Functions | On Delay, Interval On, Flasher (OFF 1st), Flasher (ON 1st), Off Delay, Single Shot, Watchdog, Single Shot (Trailing Edge), Repeat Cycle (OFF 1st), Repeat Cycle (ON 1st), Delayed Interval, Triggered Delayed Interval, On/Off Delay, Single Shot-Flasher, |
| Status Indicator | Green when powered, red when the relay is energized |
| Contact Configuration | 1C SPDT |
| Output Rating | 10 A at 240 V AC, 10 A at 30 V DC |
| Pilot Duty | B300 & R300; AC15 & DC13 |
| Input Voltage | 48V AC/DC |
| Termination Style | Plug In |
| Mounting Type | Socketable |
| Socket Family | 8 Pin Octal |
| Required Socket | 70169-D |
| Operating Temperature | -28...+65 °C (-40...+85 °C) |
| Approvals | UL Recognized (E109466), CSA Certified (LR45565), CE |
| Setting Accuracy (%) | +0.1% of set time or +50 ms, whichever is greater, at constant voltage and temperature |
| Repeatability (%) | +0.1% of set time or +0.02 s, whichever is greater, at constant voltage and temperature |
| Start-Up Time | 0.05 s |
| Maintain Function Time | 0.01 s |
| Mechanical Life | 10,000,000 cycles (100,000 cycles) |
| Input Operating Range | +10%/-15% of nominal, AC at 50/60 Hz and DC |
| Rated Power | 2 VA |