Repeat Accuracy (constant voltage and temperature)
Constant Voltage & Temperature w/i specifications: +0.1% of set time or +0.02 seconds, whichever is greater For Variable Voltage & Temperature w/i specifications: +1% of set time or +0.02 seconds, whichever is greater
Reset Time
On Delay/Interval/Flasher: 0.1 Seconds • Off Delay/Single Shot: 0.04 Seconds
Setting Accuracy
Constant Voltage & Temperature w/i specifications: +0.1% of set time or +50ms, whichever is greater For Variable Voltage & Temperature w/i specifications: +1% of set time or +50ms, whichever is greater
Start-up Time
(Time from when power is applied until unit is timing) 0.05 Seconds for all units
Temperature
Operating: -28o to 65oC (-18o to 149oF); Storage: -40o to 85oC (-40o to 185oF)
Initiating Units with Control Switch Triggers:
Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds.
Voltage Tolerance
AC Operation: +10/-15% of nominal at 50/60 Hz., DC Operation: +10/-15% of nominal.
Series Features
TD-7 Series Time Ranger™ PROGRAMMABLE | MULTI-RANGE | Digital-Set
Series Description:The TD-7 series of time delay relays offer an easy and accurate way to select any time delay between 50ms and 999 hours. Programming is accomplished by using a pushbutton thumbwheel to select one of seven built-in time ranges and three pushbutton thumbwheels to digitally set the time delay required. This method provides a greater setting accuracy than is found on other units with an analog potentiometer. An LED indicates timing mode and time out condition.
Multi-function versions available.
Pushbutton Thumbwheels for digital set of time delay