Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Macromatic |
| Manufacturer Product Number | TR-6512U |
| Description | TDR; 0.05 s...100 h; Repeat Cycle (On 1st); 24-240V AC & 12-125V DC |
| Datasheet | Download Datasheet |
The Macromatic TR-6512U is a time delay relay with 2C DPDT output and rated 10 A at 240 V AC, 10 A at 30 V DC, driven by a 24-240V AC & 12-125V DC input.
It is adjustable from 0.05 s to 100 h, over sixteen selectable scales and set by a rotary range switch and knob.
It is a Repeat Cycle (On 1st) timer.
Upon application of control voltage, the output is energized and the time delay (t1) begins. At the end of the time delay (t1), the output is de-energized and remains in that condition for the time delay (t2). At the end of this time delay, the output is energized and the sequence repeats until input voltage is removed.
It has Socketable mounting and Plug In terminals.
| Category | |
| Manufacturer | Macromatic |
| Model | TR-6 |
| Output Technology | Electromechanical Relay |
| Timing Function | Repeat Cycle (On 1st) |
| Delay Time | 0.05 s...100 h |
| Time Ranges | A 0.05-0.5 s, B 0.1-1 s, C 0.5-5 s, D 1-10 s, E 3-30 s, F 6-60 s, G 0.2-2 min, H 0.5-5 min, I 1-10 min, J 3-30 min, K 6-60 min, L 0.2-2 h, M 0.5-5 h, N 1-10 h, O 2.4-24 h, P 10-100 h |
| Timing Adjustment Method | Rotary range switch and knob |
| Timing Initiate Method | Input Voltage |
| Contact Configuration | 2C DPDT |
| Output Rating | 10 A at 240 V AC, 10 A at 30 V DC |
| Pilot Duty | B300 & R300; AC15 & DC13 |
| Input Voltage | 24-240V AC & 12-125V DC |
| Termination Style | Plug In |
| Mounting Type | Socketable |
| Socket Family | 8 Pin Octal |
| Required Socket | 70169-D |
| Operating Temperature | -28...+65 °C (-40...+85 °C) |
| Approvals | UL Recognized (E109466), CE |
| Setting Accuracy (%) | Maximum setting +5%/-0%, minimum setting +0%/-50% |
| Repeatability (%) | +0.1% or +50 ms, whichever is greater, at constant voltage and temperature |
| Start-Up Time | 0.05 s |
| Maintain Function Time | 0.01 s |
| Mechanical Life | 10,000,000 cycles (100,000 cycles) |
| Input Operating Range | 20.4...264 V AC at 50/60 Hz, 10.2...137.5 V DC |
| Rated Power | 3 VA |