Product Description
Description: Time Delay Relay • True Delay on Break • Control Voltage: 120V AC/DC • Contact Configuration: 2C DPDT • Output Current: 10 Amps • Mounting: 8 Pin Plug-in • Timing Range: Multi-range (16): 0.05 seconds to 30 minutes • Timing Adjustment: Analog
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Control Voltage | 120V AC/DC |
Contact Configuration | 2C DPDT |
Output Current | 10 Amps |
Mounting | 8 Pin Plug-in |
Timing Range | Multi-range (16): 0.05 seconds to 30 minutes |
Timing Adjustment | Analog |
Load (Burden) | Maximum of 2 VA for all voltages. These products draw a brief inrush current on power-up of 1A to charge the internal circuitry. |
Setting Accuracy | Maximum Setting (Adjustable): +5%, -0% Minimum Setting (Adjustable): +0%, -50% |
Repeat Accuracy (constant voltage and temperature) | +50ms |
Reset Time | 0.1 Seconds |
Start-up Time | (Time from when power is applied until unit is timing) 0.05 Seconds |
Maintain Function Time | (Time unit continues to operate after power is removed) 0.01 Seconds for all units |
Temperature | -28o to 65oC (-18o to 150oF) |
Output Contacts | DPDT 10A @ 240V AC; 8A @ 28V DC, 1/2 HP @ 240V AC, 1/4HP @ 120V AC B300 & R300 |
Mechanical Life | 2,000,000 operations |
Full Load Life | 100,000 operations |
Series Features |
TR-6 Series Time Ranger PROGRAMMABLE | MULTI-RANGE TRUE OFF DELAY |
Series Description: A True Off Delay time delay relay is designed to replace the functionality of pneumatic time delay relays which are very large, expensive and not very accurate. Unlike standard electronic Off Delay time delay relays (see page 29), a True Off Delay does not require a trigger switch or the continuous application of control voltage. Instead, these products keep the logic circuit and relay energized during the Off Delay (Delay on De-energization) period with an onboard power source. The Macromatic TR-606 Series is a perfect product to use when a trigger switch is not available in the circuit or when the application is to replace the functionality of a pneumatic time delay relay. These products come with 8 separate timing ranges covering 0.5 seconds – 30 minutes which are easy to select & setup with one rotary switch & potentiometer. |
Operation: Upon application of control voltage, the output is energized. When the control voltage is removed, the time delay (t) begins. At the end of the time delay (t), the output is de-energized. Control voltage must be applied for a minimum of 0.5 seconds to assure proper operation. Any application of the control voltage during the time delay (t) will reset the time delay. No external trigger is required. |
|