Product Description
Description: Intrinsically Safe Relay • Function: Operating configuration applied to single channel relays • Control Voltage: 102-132V AC & 10-125V DC • Number of Channels: 1 • Enclosure Style: 17.5mm • Mounting: Mounts on 35mm DIN-rail or panel-mounted with two #8 screws when DIN-rail clips are fully extended from under the enclosure.
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Function | Operating configuration applied to single channel relays |
Control Voltage | 102-132V AC & 10-125V DC |
Number of Channels | 1 |
Enclosure Style | 17.5mm |
Load (Burden) | 2VA Maximum |
Input Switch Open Circuit Voltage | 10V DC |
Output Contacts | SPST-NO (Form A) 3A Resistive @ 125V AC @ 60oC & 30V DC Resistive, Pilot Duty Rating D300 SPST-NO (Form A) 5A Resistive @ 125V AC @ 40oC & 30V DC Resistive, Pilot Duty Rating D300 |
Electrical Life | 50,000 Closures @ Full Load AC |
Mechanical | 5 Million Closures @ No Load |
Response Times | < 50ms |
Operating Temperature | -28o to + 60o C (-18o F to +140o F) |
Storage Temperature | -55o to +85o C (-67o to 185o F) |
Insulation Voltage | 1500 V AC between coil & contacts 750 V AC between open contacts 1500 V AC between hazardous and safe circuits |
Wire Sizes | One #14-24 AWG Conductor or Two #16 or 18 AWG Conductors |
Mounting | Mounts on 35mm DIN-rail or panel-mounted with two #8 screws when DIN-rail clips are fully extended from under the enclosure. |
Series Features |
ISE Series 17.5 MM INTRINSICALLY SAFE BARRIER RELAYS |
Series Description: The ISE Series of Intrinsically Safe Barrier relays provide a safe and reliable method to control a single load (motor starters, relays, etc.) with a single input device (switches, sensors, etc.) located in a hazardous area. The compact 17.5mm wide enclosure can be both mounted on 35mm DIN rail or panel-mounted with two screws. Terminals for the input devices from the Hazardous area are on the bottom for easy access in the enclosure to incoming field wiring from the hazardous area. |
Operation: Each ISE Series relay consists of an intrinsically safe input, a corresponding normally-open relay output, and a bi-color LED for status indication. With input voltage applied, the LED will be ON (GREEN) to indicate power is applied. When the output contact is closed, the LED is ON (ORANGE). The ISE series comes in Standard and Inverted configurations Configurations Standard Logic (ISEUR1): When the input device is closed, the corresponding output contact is closed. When the input device is open, the corresponding output contact is open. Inverse Logic (ISEUR1V): When the input device is open, the corresponding output contact is closed. When the input device is closed, the corresponding output contact is open. |
|