Product Description
Description: Current Monitor Relays • Type: Overcurrent • Coil Voltage: 110-120 VAC • Contact Configuration: 1C SPDT • Mounting: 8 Pin Plug-in • Current Range Monitored: 1 - 10 Amps • Current Settings: Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) • Drop-Out Setting: Adjustable (From 50-95% of Pick-Up) • Indicator LED: Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized.
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Type | Overcurrent |
Coil Voltage | 110-120 VAC |
Contact Configuration | 1C SPDT |
Mounting | 8 Pin Plug-in |
Current Range Monitored | 1 - 10 Amps |
Current Settings | Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) |
Drop-Out Setting | Adjustable (From 50-95% of Pick-Up) |
Indicator LED | Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. |
Input Voltage Tolerance | AC Operation: +10/-15% of nominal at 50/60 Hz. |
Life | Mechanical: 10,000,000 operations, Full Load: 100,000 operations |
Load (Burden) | Less than 5VA |
Mounting Needs | Requires an 8 or Plug-in 11 Pin Round socket--see page 16 of Catalog. |
Output Contacts | 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) |
Pick-up Setting | Adjustable |
Reset | Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. |
Response Times | Pick-up: Adjustable 0.1-10 seconds, Drop-out: Fixed 100ms |
Temperature | -28° to 55°C (-20° to 131°F) |
Series Features |
COKP Series AC OVERCURRENT |
Series Description: Current sensing relays can be used in several applications where protection of sen- sitive or expensive equipment against over or under current conditions is required, such as detecting (sensing) conveyor jam-up conditions, machine tool wear, no load conditions or monitoring status of heater or lamp loads. The COKP Series is used to detect an overcurrent condition. The pick-up current setting is user-adjustable within one of three ranges as shown in the Product Selec- tion Table below. An external current transformer can be used to extend the range of these products. The drop-out setting is adjustable from 50-95% of the selected pick-up setting. The relay will energize when the monitored AC current is above the pick-up setting for a period longer than the adjustable time delay (t) of 0.1-10 seconds. This delay prevents nuisance tripping caused by inrush currents. It will de-energize when the monitored AC current is below the drop-out setting. |
|