Product Description
Description: 3 Phase Voltage Monitor
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage (V) | 200 - 480 Vac |
Maximum Input Power | 5 |
Input AC Line Frequency (Hz) | 50 / 60 |
Output Load Rating (VA) | Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac |
Timing Accuracy (%) | 5% ±1 s |
Rapid Cycle Timer (s) | 0; 2 - 500 s |
Restart Delay Range | Restart Delay After All Faults: 2 - 500 s |
Repeat Accuracy (%) | Voltage: ±0.5% |
Trip Delay Range | Voltage/Unbalance/Frequency faults/single-Phase faults: 1 - 50 s |
Overvoltage Reset Voltage (%) | 97% of HV Setting |
Undervoltage Reset Voltage (%) | 103% of LV Setting |
Voltage Unbalance Reset (%) | UB Setting -1% |
Voltage Accuracy (%) | ±1% |
Over/Under Frequency (%) | Low: 35 Hz - HF setting; High: LF setting - 75 Hz |
Protection Class | IP20; NEMA 1 (finger safe) |
Address | A01 - A99 |
Termination Type | Torque: 7 in-lbs |
Mounting Method | Surface mount (4 - #8 screws) or DIN rail mount |
Operating Temperature | -20° to 70°C (-4° to 158°F) |
Storage Temperature (F/C) | -40° to 80°C (-40° to 176°F) |
Humidity | 10 - 95% non-condensing per IEC 68-2-3 |
Dimensions | 3.05 H x 3.85 W x 5.05 D in. (77.5 x 97.8 x 128.3 mm) |
Series Features |
601 Series - 3-Phase Voltage & Frequency Monitor |
Series Description: he 601 series is a fully-programmable voltage monitor designed to protect three-phase motors from loss of any phase (single-phasing), phase reversal, low- or high-voltage, voltage unbalance, low- or high-frequency, and rapid cycling. When a harmful condition is detected, the 601s output relay is deactivated after the specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for the programmed restart delay (RD2). This monitor can be used as a stand-alone product or networked with an RM-1000, RM-2000, PLC, computer, or SCADA system. Eleven setpoints are viewable with the three-digit LED display or from a networked device: low voltage high voltage voltage unbalance low frequency high frequency RS485 address trip delay for voltage/frequency faults trip delay for single-phase faults rapid-cycle timer (RD1) restart delay after all faults (RD2) type of restart after all faults (manual or automatic) Six parameters are viewable while the motor is running: L1-L2 voltage L2-L3 voltage L1-L3 voltage average voltage voltage unbalance (%) frequency When used with the RS485MS-2W communications module, the 601 can communicate with most Modbus RTU master devices. Voltage conditions can be monitored and setpoints can be changed remotely using Solutions software, an RM1000, RM2000, or other device. |
Series Applications: Oil rigs, Compressors and fans, HVAC, Heat, well, and sump pumps, Small conveyer motors |
|