Product Description
Description: 3-Phase Line-Load Volt.Mon./475-600V/adj.VUB,TD,RD
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage (V) | 475 - 600 Vac |
Maximum Input Power | 6 |
Input AC Line Frequency (Hz) | 50 / 60 (50 will increase all delay timers by 20%) |
Output Form | SPDT |
Output Load Rating (VA) | Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A |
Restart Delay Range | Manual; 2 - 300 s adjustable |
Repeat Accuracy (%) | ±0.1% |
Trip Delay Range | Under/Over and Unbalance Voltage: 2 - 30 s adjustable; single-Phase faults (>25%UB): 2 s |
Trip Point Accuracy (%) | ±1% |
Overvoltage Trip Voltage (%) | 1.1 |
Overvoltage Reset Voltage (%) | 1.07 |
Undervoltage Trip Voltage | 0.9 |
Undervoltage Reset Voltage (%) | 0.93 |
Voltage Unbalance Trip Point (%) | 2 - 8% adjustable |
Voltage Unbalance Reset (%) | Trip setting minus 1% |
Termination Type | Torque: 7 in-lbs; Wire Size: 12 - 18 AWG |
Mounting Method | #8 screws |
Operating Temperature | -40° to 70°C (-40° to 158°F) |
Storage Temperature (F/C) | -40° to 80°C (-40° to 176°F) |
Dimensions | 2.93 H x 5.27 W x 2.95 D in. (74.4 x 133.9 x 74.9 mm) |
Series Features |
455 Series - 3-Phase Voltage/Phase Monitor |
Series Description: The 455 series is a three-phase, dual-range voltage monitor that combines load and line side monitoring for a complete protection solution. Load side monitoring alerts the user to contactor failure or impending contactor failure. Line side monitoring protects the motor from damaging fault conditions that may be present prior to the motor starting. This is unique because with other line/load side monitors, the motor must be started before a voltage fault is detected. With the 455 series, the motor is fully protected at all times. This voltage monitor protects 190480 V ac, 50*/60 Hz motors regardless of their size. It automatically selects between the 200 V and 400 V range when the user selects the nominal voltage setpoint. Other adjustments include a 230 second trip delay, a 2300 second restart delay (and manual restart), and a voltage unbalance trip point of 28%. The voltage monitors circuitry is powered through the line side connections so there is no need for separate control power, making it easy to install. Equipped with an infrared LED, the 455 series can communicate with the optional hand-held diagnostic tool, Informer-MS, to obtain valuable information such as real-time voltage, voltage unbalance on both line and load sides, motor run hours, last 20 faults, last 32 motor starts, high- and low-voltage trip points, voltage unbalance trip point, restart and trip delay settings, LED status, and more. |
Series Applications: Oil rigs, Compressors and fan motors, HVAC, Heat, well, and sump pumps, Small conveyer motors |
|