Product Description
Description: Remote Monitor for up to 16 devices/NEMA4
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage (V) | 12 - 24 Vdc (Supplied by RS485MS-2W) |
Input Current Range (A) | 0.1 (max.) |
Protection Class | NEMA 4X |
Communications Protocol | Modbus RTU |
Communications Interface | RS-485 |
Communications Range | 50 ft; 4000 ft with separate isolated power supply |
Communications Baud Rate (Bps) | 1200 -19200 |
Address | 1-99 (max 16 per RM-1000) |
Termination Type | Depluggable; 3 in-lbs. |
Mounting Method | Surface mountable on backplane using 4 screws; Panel thickness: 0.03 in |
Operating Temperature | -40° to 70°C (-40° to 158°F) |
Storage Temperature (F/C) | -40° to 80°C (-40° to 176°F) |
Humidity | Up to 85% non-condensing |
Dimensions | 3.62 H x 4.54 W x 0.9 D in. (91.9 x 115.4 x 22.9 mm) |
Series Features |
RM1000 SERIES - Remote Monitor |
Series Description: The RM-1000 Series is a motor-monitoring device to be used in conjunction with the 777 family of products (excluding the P1 Series), 77C family of products and the 601 voltage monitors, via Modbus protocol with a communications module. The RM-1000/777 motor management system combines unsurpassed electronic motor protection and critical, user- friendly, motor monitoring. The RM1000 Series can monitor up to 16 MotorSaver® and/or PumpSaver® units through an RS-485 network using Modbus RTU protocol. A second communication port allows monitoring and control of up to 99 MotorSaver® and/or PumpSaver® units from a computer, PLC, DCS or SCADA system and can be accessed from the host computer or PLC with the RM1000 acting as a repeater for any of its motor protectors. In addition to the monitoring functions, the RM-1000 can be used to reset a tripped MotorSaver® or PumpSaver®. The RM1000 Series is easily mounted remotely and improves safety for service and operations personnel by allowing them to control and monitor the device without opening the electrical cabinet. Using the RM1000 is a simple, cost-effective method for aiding compliance with arc flash safety regulations. The enclosure and keypad assembly is water and ultraviolet light resistant. The enclosure is NEMA 3R or NEMA 4X (optional) rated. The RM1000 and RM1000 NEMA 4 also carry a UL Type 12 rating, whereas the RM-1000-3R does not carry the UL Type 12 rating due to added weep holes. The added weep holes in the RM1000-3R make it suitable for applications subjected to condensing moisture/humidity. |
|