Product Description
Description: 1-Phase PumpSaverPlus/230V/5-15hp/CT required
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Input Voltage (V) | 230 Vac |
Maximum Input Power | 5 |
Input AC Line Frequency (Hz) | 50 / 60 (50 will increase all delay timers by 20%) |
Input Load Range (hp) | 5 - 15 (external current transformer required) |
Output Form | SPST |
Output Load Rating (VA) | A300; 720 VA @ 240 Vac (10 A max.) |
Rapid Cycle Timer (s) | 4 restarts allowed in 60 s period |
Restart Delay Range | Over/Under Voltage: 2 s; All other faults: Manual; 2 - 225 m |
Trip Delay Range | Overcurrent: 5 s; Dry-well: 4 s |
Overvoltage Trip Voltage (%) | 265 Vac |
Undervoltage Reset Voltage (%) | 190 Vac |
Overcurrent Trip Class | 125% of calibration point |
Underload (%) | Adjustable (70 to 90% of calibrated run power) |
Termination Type | Torque: 13 in-lbs; Wire: Solid or stranded 10 - 22 AWG |
Mounting Method | #8 screws |
Operating Temperature | -40° to 55°C (-40° to 131°F) |
Dimensions | 2.93 H x 5.25 W x 2.91 D in. (73.7 x 133.4 x 74 mm) |
Series Features |
235P Series - Single-Phase Pump Monitor |
Series Description: The Littelfuse 235P is designed to protect 5-15 hp, 230 V, single-phase pumps from dry-well, dead-head, jammed impellers, rapid-cycle, and overvoltage and undervoltage conditions. A calibration adjustment allows the 235P to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations causing overcurrent and undercurrent. When an abnormality such as loss of suction is detected, the 235P deactivates its output relay and directly disconnects the pump motor. The 235P communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time, and last faults. An external current transformer is required for operation (sold separately). Special considerations for pump cables larger than #10 AWG: In some cases where larger motors are installed with deep- set pumps, pump cables are used that exceed the relays terminal size. In these conditions, a short splice of #10 AWG or #12 AWG may be a solution at the control box. Note: All local, state, and national electric codes should be followed when applying this solution. |
Series Applications: Used for single-phase pump protection needs |
|