Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Symcom / Littelfuse |
| Manufacturer Product Number | 520CS-115 |
| Description | Current Monitor Relay; AC Over/Undercurrent; 5 A via ext. CTs; 115V AC |
| Datasheet | Download Datasheet |
The Littelfuse SymCom 520CS-115 is a 3-phase pump current monitor (current monitoring relay). 3-phase pump current monitor: overcurrent, undercurrent, current unbalance, single phasing, phase reversal and rapid cycling; restarts after programmable delays (RD1 rapid-cycle, RD2 after overload, RD3 after underload) -- for submersible, booster, RO, centrifugal, vertical turbine, oil well and chemical pumps. It trips on over and undercurrent. Control power: 115V AC.
Current range: Up to 5 A full scale (CT secondary). Trip delay: Programmable; 0.5 s fixed on single-phase or reverse-phase. Restart delay: Programmable RD1 / RD2 / RD3 restart delays. Reset: Automatic after the restart delay, with programmable restart counts. Start-up delay: 0-50 s programmable motor acceleration time. Setting accuracy: Trip point ±2%; timing ±25%, ±1 s. Status: 3-digit alphanumeric display: setpoints and last fault.
Output: SPDT, 10 A general purpose. Sensor: Three external current transformers (sold separately). Mounting: Surface Mount. Dimensions: 209.55 x 133.35 x 82.55 mm (8.25 x 5.25 x 3.25 in), H x W x D. Power: 5 W.
It operates from 0 to +70 °C. Approvals: UL 508, CSA C22.2.
| Category | |
| Manufacturer | Symcom / Littelfuse |
| Model | 520CS |
| Part Status | Discontinued |
| Monitoring Function | AC Over/Undercurrent |
| Sensor Type | Three external current transformers (sold separately) |
| Current Range | Up to 5 A full scale (CT secondary) |
| Output Mode | 3-phase pump current monitor: overcurrent, undercurrent, current unbalance, single phasing, phase reversal and rapid cycling; restarts after programmable delays (RD1 rapid-cycle, RD2 after overload, RD3 after underload) -- for submersible, booster, R |
| Input Voltage | 115V AC |
| Input Operating Range | 100...130 V |
| Trip Delay | Programmable; 0.5 s fixed on single-phase or reverse-phase |
| Sensing Delay on Power-Up | 0-50 s programmable motor acceleration time |
| Setting Accuracy | Trip point ±2%; timing ±25%, ±1 s |
| Reset Delay | Programmable RD1 / RD2 / RD3 restart delays |
| Reset Method | Automatic after the restart delay, with programmable restart counts |
| Status Indicator | 3-digit alphanumeric display: setpoints and last fault |
| Contact Configuration | SPDT |
| Output Rating | 10 A general purpose |
| Mounting Type | Surface Mount |
| Dimensions | 209.55 x 133.35 x 82.55 mm (8.25 x 5.25 x 3.25 in), H x W x D |
| Rated Power | 5 W |
| Operating Temperature (Storage) (°C) | 0...+70 |
| Approvals | UL 508, CSA C22.2 |