Product Attribute
| Attribute Value
|
| Watts | 75W |
| Rated Voltage | 24 VDC |
| Rated Current | 3.2A |
| Material | Metal Frame |
| Input Voltage | 100 to 240V AC |
| Cover | Standard cove |
| Termination Style | Vertical terminal block |
| Voltage Range | 88 to 264V AC / 125 to 375V DC |
| Frequency | 47 to 63 Hz |
| Input Current | 1.8A max. |
| Inrush current (Ta = 25°, cold start) | at 115V AC: 30A typ. / at 230V AC: 50A typ. |
| Leakage Current | 1.5mA max. |
| Efficiency (Typical) | 0.84 |
| Adjustable Voltage Range | ±10% |
| Output Holding Time | 14 ms typ. (100V AC) / 60 ms minimum (230V AC) |
| Start Time | 1000 ms max. (230V AC input, rated output) |
| Rise Time | 30 ms max. (230V AC input, rated output) |
| Input Fluctuation | 0.5% max. |
| OverLoad Fluctuation | 5V: ±2% max. 12V, 24V: ±1% max. |
| Temperature Change (–10 to +50°C) | 0.04% / °C max. (–10 to +45°C) |
| Overcurrent Protection | 105% min. (auto reset) |
| Over voltage Protection | Intermittent operation or output off at 115% min. |
| Operation Indicator | LED (green) |
| Dielectric Strength | Between input and output terminals: 3,000V AC, 1 minute Between input terminal and housing: 2,000V AC, 1 minute Between output terminal and housing: 500V AC, 1 minute |
| Insulation Resistance | 100M? minimum, 500V DC megger (between input and output terminals, between input and ground terminals) |
| Operating temperature | –10 to +70°C (no freezing, see output derating) |
| Operating humidity | 20 to 85% RH (no condensation) |
| Storage temperature | –40 to +85°C (no freezing) |
| Storage humidity | 10 to 95% RH (no condensation) |
| Vibration resistance | 10 to 55 Hz, 20m/s^{2} constant, 2 hours each in 3 axes |
| Shock resistance | 200m/s^{2} , 1 shock each in 3 axes |
| Safety Standards | IEC/EN60950-1, UL60950-1, CSA C22.2 No. 60950-1 |
| Dimensions (mm) (terminal part except | 95H × 38W × 129D |
| Weight (approx.) | 500g |
| Terminal screw (horizontal type) | M3.5 |