Product Description
Description: Frame • Action: Pull • Coil Voltage: 12 VAC • Maximum Stroke: .300 In. • Duty: Intermittent • Construction: C Frame • Power: 12 VA • Resistance (Ohms): 6.3
Product Information | Resources |
|
|
Specifications |
Product Attribute | Attribute Value |
Action | Pull |
Coil Voltage | 12 VAC |
Maximum Stroke | .300 In. |
Duty | Intermittent |
Construction | C Frame |
Power | 12 VA |
Resistance (Ohms) | 6.3 |
Typical Force oz [N] 100% Voltage, 77°F [25°C], Stroke @ 0.000 | 45[12.5] |
Typical Force oz [N] 100% Voltage, 77°F [25°C], Stroke @ 0.125 | 5[1.4] |
Typical Force oz [N] 100% Voltage, 77°F [25°C], Stroke @ 0.250 | 1.7[0.5] |
Coil Termination | Wire leads 24 AWG |
Coil Treatment | Tape Wrapped |
Insulation Class | Class A Rating - 105ºC (221°F) Max. |
Dielectric Strength | 30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute |
Size | 0.768 [19.5] (L) x 0.687 [17.4] (W) x 0.765 [19.4] (H) (See dimensional drawing on page 2) |
Forces | See Datasheet |
Plunger Diameter | Ø 0.3125 [7.9] |
Plunger Guide Material | Plastic |
Mounting | 2X #6-32 UNC-2B Mounting Holes |
Weight | Plunger - 0.3 oz [9.0 gms], Total - 1.0 oz [28.4 gms] |
Life Expectancy | 250,000 Cycles (Dependent on load conditions) |
Agency Approval | UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105 |
Series Features |
C4 Grame Solenoid |
Series Description: Two position linear solenoid with C-frame construction. |
|