Product Description
Description: Photo-electric Sensors • Sensing Method: Background Suppression • Sensing Distance: 7.874" (200mm) • Voltage - Supply: 10V ~ 30V • Response Time: 1ms • Output Configuration: Push-Pull, NPN/PNP • Light Source: Infrared (850nm) • Connection Method: Cable • Ingress Protection: IP67, IP68, IP69K • Cable Length: 78.74" (2m) • Adjustment Type: Adjustable, Potentiometer
| Product Information | | Resources |
| Manufacturer | Carlo Gavazzi | | Product Category | Sensor | | Product Sub Category | Photo-electric Sensors | | Series | |
| | |
Product Attribute
| Attribute Value
|
| Sensing Method | Background Suppression |
| Sensing Distance | 7.874" (200mm) |
| Voltage - Supply | 10V ~ 30V |
| Response Time | 1ms |
| Output Configuration | Push-Pull, NPN/PNP |
| Light Source | Infrared (850nm) |
| Connection Method | Cable |
| Ingress Protection | IP67, IP68, IP69K |
| Cable Length | 78.74" (2m) |
| Adjustment Type | Adjustable, Potentiometer |
| Operating Temperature | -25°C ~ 60°C (TA) |
| PD30ETBx20BPxxIO - IO-Link Photoelectric Background Suppression sensors with IO-Link communication |
Series Description: The PD30ETBx20BPxxIO stainless steel sensors are built with high-quality materials and designed for harsh environments.
They are designed for use in environments where high-pressure cleaning, cleaning agents and disinfectants are used on a daily basis.
The strong stainless steel (AISI316L) together with high-quality plastic materials like PEEK, PPSU, and PES sealings of FKM ensure a safe and excellent mechanical resistance.
The sensor housing has the IP69K rating as well as approval by ECOLAB for cleaning and disinfection agents.
The compact sensor design is ideally suited to confined spaces. |
- Red or infrared sensor with IO-Link with a adjustable distance of 25 to 200 mm, either by trimmer or via IO- Link.
- Application functions: Pattern Recognition, Speed & Length, Divider function and Object & Gap Monitoring.
- Neighbour Immunity, selectable up to 3 sensors
- Easy customization to specific OEM requests by use of the build in IO-Link functionalities.
- The output can be operated either as a standard switching output or in IO-Link mode.
- Fully configurable via output IO-Link v 1.1. Electrical outputs can be configured as PNP / NPN / Push-Pull / External input, normally open or normally closed.
- Timer functions can be set, such as ON-delay, Off- delay, and one shots.
- Logging functions: Temperatures, detecting counter, power cycles and operating hours.
- Detection modes Single point, two point, windows and foreground suppression (FGS) mode.
- Logic functions: AND, OR, XOR and Gated SR-FF.
- Analogue output: In IO-Link mode the sensor will generate 16 bit analogue process data output representing various selectable process data such as received signal level.
|