Product Description
Description: Time Delay Relays • Delay-on-Dropout • Input Voltage: 24VDC • Contact Configuration: 2C DPDT • Timing: Fixed • Time Range: 2 sec • Termination: 8 pin Octal • Current: 4 Amp
Product Information | Resources |
|
|
This product is Unavailable - the factory shut down on June 2023. Please Contact Customer Service for help with Cross Reference / Replacement |
Specifications |
Product Attribute | Attribute Value |
Input Voltage | 24VDC |
Contact Configuration | 2C DPDT |
Timing | Fixed |
Time Range | 2 sec |
Termination | 8 pin Octal |
Current | 4 Amp |
Contact Material | Gold Clad Silver Alloy |
Maximum Switching Power | 1000 VA, 90W |
Maximum Switching Voltage | - 250V AC, 48V DC |
Expected Life @ 25°C | 100 Million operations, Mechanical Electrical: 100,000 operations at 4A 250V AC 200,000 operations at 3A 30V DC |
Temperature Range: Operating and storage: | Ambient: -40°C to +65°C (-40°F to +149°F) |
Enclosure | Black plastic case. Knob adjustable models have a dial scale for reference only. |
Weight | 4 oz (114g) approx. |
Timing Adjustment | Knob adjustable potentiometer. |
Timing Tolerance | Fixed Units: ± 5% |
Adjustable Units | -0 to +25% of maximum specified delay time. |
Repeatability | ±5% |
Initial Dielectric Strength | Between open contacts: 750V RMS, Between adjacent contacts: 1000V RMS, Between contacts & coil: 1500V RMS |
Power Requirement | AC units: 2 VA or less; DC units: 2 Watts or less |
Transient Protection | 1 JOULE MOV |
Polarity Protection | On DC units - Yes. |
Series Features |
DOD Series TDR |
Operation: Upon the application of input voltage the relay immediately energizes. The timing cycle begins when input voltage is removed. When the timing cycle is complete, the relay will de-energize. The relay contacts will reset when input voltage is reapplied. |
|