Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Amperite |
| Manufacturer Product Number | 24AP1-10MDC |
| Description | TDR; 1...10 min; 24 V AC; DPDT (2 form C); 8 Pin (Octal); Plug-in (octal) |
| Datasheet | Download Datasheet |
The Amperite 24AP1-10MDC is a time delay relay with DPDT (2 form C) output and rated 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC, driven by a 24 V AC input.
It is adjustable from 1 to 10 min and set by a knob adjustable potentiometer.
It is a Delay on operate (delay on make) timer.
Delay on operate timing cycle begins upon application of input power. The relay contacts transfer at the end of the delay period and will remain transferred until input voltage is removed. Reset occurs when input voltage is removed.
It has Plug-in (octal) mounting and Plug In, 8 Pin (Octal) terminals.
| Category | |
| Manufacturer | Amperite |
| Part Status | Discontinued |
| Output Technology | Relay (electromechanical contacts) |
| Timing Circuit | Solid state CMOS digital |
| Timing Function | Delay on operate (delay on make) |
| Delay Time | 1...10 min |
| Timing Adjustment Method | Knob adjustable potentiometer |
| Contact Configuration | DPDT (2 form C) |
| Output Rating | 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC |
| Input Voltage | 24 V AC |
| Termination Style | Plug In, 8 Pin (Octal) |
| Mounting Type | Plug-in (octal) |
| Enclosure | White plastic case; knob adjustable models have a dial scale for reference only |
| Operating Temperature | -45...+70 °C (-60...+105 °C) |
| Approvals | UL (E96739 (M)), CSA (LR62586) |
| Setting Accuracy (%) | Fixed units: +/-5% (1% units available at extra cost); adjustable units: -0 to +10% of maximum specified delay time (minimum specified value or less at low end) |
| Repeatability (%) | +/-1% |
| Timing Cycle Interrupt Transfer | None |
| Reset | Upon interruption of power |
| Mechanical Life | 10 million operations cycles (100,000 operations minimum at rated loads (@ 25 C) cycles) |
| Rated Power | AC units: 3 VA or less; DC units: 3 W or less |