| Manufacturer | Amperite |
| Manufacturer Product Number | 12DP1-60SLDC |
| Description | Time Delay Relay; 1...60 s; 12 V DC; DPDT (2 form C); 11 Pin Spade Terminal |
| Datasheet | Download Datasheet |
The Amperite 12DP1-60SLDC is a time delay relay with DPDT (2 form C) output and rated 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC, driven by a 12 V DC input.
It is adjustable from 1 to 60 s and set by a knob adjustable potentiometer.
It is a Delay on operate (delay on make) timer.
Delay on operate timing cycle begins upon application of input power. The relay contacts transfer at the end of the delay period and will remain transferred until input voltage is removed. Reset occurs when input voltage is removed.
It has Plug-in (11-pin spade) mounting and 11 pin spade terminals.
| Category | |
| Manufacturer | Amperite |
| Part Status | Discontinued |
| Output Technology | Relay (electromechanical contacts) |
| Timing Circuit | Solid state CMOS digital |
| Timing Function | Delay on operate (delay on make) |
| Delay Time | 1...60 s |
| Timing Adjustment Method | Knob adjustable potentiometer |
| Contact Configuration | DPDT (2 form C) |
| Output Rating | 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC |
| Input Voltage | 12 V DC |
| Termination Style | 11 Pin Spade Terminal |
| Mounting Type | Plug-in (11-pin spade) |
| Enclosure | White plastic case; knob adjustable models have a dial scale for reference only |
| Operating Temperature | -45...+70 °C (-60...+105 °C) |
| Approvals | UL (E96739 (M)), CSA (LR62586) |
| Setting Accuracy (%) | Fixed units: +/-5% (1% units available at extra cost); adjustable units: -0 to +10% of maximum specified delay time (minimum specified value or less at low end) |
| Repeatability (%) | +/-1% |
| Timing Cycle Interrupt Transfer | None |
| Reset | Upon interruption of power |
| Mechanical Life | 10 million operations cycles (100,000 operations minimum at rated loads (@ 25 C) cycles) |
| Rated Power | AC units: 3 VA or less; DC units: 3 W or less |