Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | Amperite |
| Manufacturer Product Number | 120AP.1-60LCIR |
| Description | Time Delay Relay; 0.1...60 s; 120 V AC; DPDT (2 form C); 11 Pin Spade Terminal |
| Datasheet | Download Datasheet |
The Amperite 120AP.1-60LCIR is a time delay relay with DPDT (2 form C) output and rated 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC, driven by a 120 V AC input.
It is adjustable from 0.1 to 60 s and set by a knob adjustable potentiometer.
It is a Triggered one-shot (triggered interval on) timer.
Input voltage must be applied continuously to operate the internal relay. The relay energizes and timing begins when the external switch is closed. At the end of the time delay period the relay will de-energize. Reset is accomplished by opening and re-closing the control switch.
It is started by external control switch closure (reset by opening and re-closing the switch).
It has Plug-in (11-pin spade) mounting and 11 pin spade terminals.
| Category | |
| Manufacturer | Amperite |
| Part Status | Discontinued |
| Output Technology | Relay (electromechanical contacts) |
| Timing Circuit | Solid state analog |
| Timing Function | Triggered one-shot (triggered interval on) |
| Delay Time | 0.1...60 s |
| Timing Adjustment Method | Knob adjustable potentiometer |
| Timing Initiate Method | External control switch closure (reset by opening and re-closing the switch) |
| Contact Configuration | DPDT (2 form C) |
| Output Rating | 10 A @ 240 V AC resistive; 15 A @ 30 V DC resistive; 15 A @ 120 V AC resistive; 1/3 HP @ 120 V AC; 1/2 HP @ 250 V AC |
| Input Voltage | 120 V AC |
| Termination Style | 11 Pin Spade Terminal |
| Mounting Type | Plug-in (11-pin spade) |
| Enclosure | Black plastic case; knob adjustable models have a dial scale for reference only |
| Operating Temperature | -45...+70 °C (-60...+105 °C) |
| Approvals | UL (E96739 (M)), CSA (LR62586-3) |
| Setting Accuracy (%) | Fixed units: +/-5%; adjustable units: -0 to +25% of maximum specified delay time (minimum specified value or less at low end) |
| Repeatability (%) | +/-5% |
| Mechanical Life | 10 million operations cycles (100,000 operations minimum at rated loads (@ 25 C) cycles) |
| Rated Power | AC units: 3 VA or less; DC units: 2 W or less |