Product Description
Description: Time Delay Relays • Delay on Make • Input Voltage: 120 VAC • Contact Configuration: 2C DPDT • Timing: Fixed • Time Range: 0.1 sec • Termination: 8-pin • Current: 10 Amp
Product Information | Resources |
|
|
This product is Unavailable - the factory shut down on June 2023. Please Contact Customer Service for help with Cross Reference / Replacement |
Specifications |
Product Attribute | Attribute Value |
Input Voltage | 120 VAC |
Contact Configuration | 2C DPDT |
Timing | Fixed |
Time Range | 0.1 sec |
Termination | 8-pin |
Current | 10 Amp |
Temperature Range: Operating and storage: | Storage: -60°C to +105°C (-76°F to +221°F) Operating: -45°C to +70°C (-49°F to +158°F) |
Enclosure | White plastic case. Knob adjustable models have a dial scale for reference only. "LC" version has a black case. |
Weight | 4 on (114g) approx. |
Timing Adjustment | Knob adjustable potentiometer. |
Timing Tolerance | Fixed Units: ±5%. Adjustable Units: -0 to +25% of maximum specified delay time. |
Repeatability | ±5% |
Release Time | 60 ms typical, 100 ms maximum. |
Timing Cycle Interrupt Transfer. | None |
Initial Dielectric Strength | Between open contacts: 1000V RMS, Between adjacent contact: 1500V RMS Between contacts & coil: 1500V RMS |
Power Requirement | AC units: 3 VA or less, DC units 3 Watts or less |
Transient Protection | 1 JOULE MOV |
Polarity Protection | On DC units - Yes. |
Series Features |
C10 Series TDR |
Operation: Delay on operate timing cycle begins upon application of input power. The relay contacts transfer at the end of the delay period and will remain transferred until input voltage is removed. Reset occurs when input voltage is removed. |
|