Get A Quote
My Account
To ensure accuracy, please note that images may be representative. Refer to the product data sheet for detailed specifications.
| Manufacturer | ATC Diversified |
| Manufacturer Product Number | TSH-24-ARC-002 |
| Description | Time Delay Relay; 0.02...2 s; Ext RT Adj; Delayed Interval; 24V AC; QC 0.250"; 1A SPST-NO |
| Datasheet | Download Datasheet |
The ATC Diversified TSH-24-ARC-002 is a solid-state delayed interval (delay-on-make, then interval) timer module for 24 V AC. The delay-on-make time (T1) is adjustable from 0.02 to 2 seconds and the interval (T2) from 0.02 to 2 seconds with an external resistor across its RT terminals.
Upon application of supply voltage the OFF delay runs; at its end the relay energizes for the ON (interval) time and then de-energizes until supply voltage is removed and re-applied.
Output: 1A SPST-NO. It has no LED indicator. Repeat accuracy: 1% maximum, no first cycle effect. Setting accuracy: Maximum setting ±10%, minimum setting +0%/-20%. Supply tolerance: ±10% of nominal; 50/60 Hz.
It is surface mounted and has 0.250 in (6.3 mm) male quick-connect terminals. It operates from 0 to +55 °C and stores from -45 to +85 °C. Approvals: UL Recognized, cUL Recognized (E55826).
| Category | |
| Manufacturer | ATC Diversified |
| Model | TSH |
| Output Technology | Solid State |
| Timing Function | Delayed Interval |
| Delay Time | 0.02...2 s |
| Second Timing Range | 0.02...2 s |
| Time Ranges | Both delays independently adjustable over the same range |
| Timing Adjustment Method | External resistor (RT terminals) |
| Timing Initiate Method | Input Voltage |
| Status Indicator | None |
| Contact Configuration | 1A SPST-NO |
| Output Rating | 1 A resistive at 24 V AC (25 VA), 1 A at 120 V AC (125 VA), 0.5 A at 240 V AC (125 VA) |
| Input Voltage | 24V AC |
| Termination Style | Quick Connect - 0.250" (6.3mm) |
| Mounting Type | Surface Mount |
| Operating Temperature | 0...+55 °C (-45...+85 °C) |
| Approvals | UL Recognized, cUL Recognized (E55826) |
| Setting Accuracy (%) | Maximum setting ±10%, minimum setting +0%/-20% |
| Repeatability (%) | 1% maximum, no first cycle effect |
| Input Operating Range | ±10% of nominal; 50/60 Hz |