| Manufacturer | ATC Diversified |
| Manufacturer Product Number | CMU-100-USD2 |
| Description | Current Monitor Relay; AC Over/Undercurrent; In = 2 A (AC 50-60 Hz) |
| Datasheet | Download Datasheet |
The ATC Diversified CMU-100-USD-2 is an AC over/undercurrent monitor for In = 2 A (AC 50-60 Hz). It watches the current against an upper and a lower limit and transfers its relay when the current leaves the band.
Sensing: direct input on terminals A1-B1 (internal shunt), true RMS. Control supply: 24-240 V AC/DC. Line: -15% / +10%; AC 50-60 Hz. Trip point: upper limit (Imax) adjustable 10-100% of In. Drop-out: lower limit (Imin) adjustable 5-95% of In. Hysteresis: 5% (functions O1, U1, W); Imax - Imin (functions O2, U2). Accuracy: 5% (mechanical setting); repeat accuracy <1%; temperature dependency <0.1%/°C. Start delay: 0.3 s. Trip delay: 0.5-10 s adjustable. Reset: automatic; latching functions (OL, UL, WL) reset by a short interruption of the supply or by turning the function switch to R.
Output: SPDT, 13 A AC1 / 13 A general purpose at 250 V AC (55 °C); breaking capacity 4000 VA AC1, 384 W DC1; switching voltage 250 V AC / 24 V DC. Mounting: DIN rail. Indicator: LEDs for supply voltage and operating status (flashing during the time delay). Approvals: cULus Listed, Industrial Control Equipment 496Y; CE. It operates from -20 to +55 °C and stores from -30 to +70 °C.
| Category | |
| Manufacturer | ATC Diversified |
| Model | CMU100 |
| Monitoring Function | AC Over/Undercurrent |
| Sensor Type | Direct input on terminals A1-B1 (internal shunt), true RMS |
| Setting Adjustment | Analog (onboard knobs: function, Imax, Imin, time delay) |
| Current Range | In = 2 A (AC 50-60 Hz) |
| Pickup Current Setting | Upper limit (Imax) adjustable 10-100% of In |
| Dropout Current Setting | Lower limit (Imin) adjustable 5-95% of In |
| Output Mode | Selectable: O1 / O2 over current, U1 / U2 under current, W window, OL / UL / WL with fault latch; the output contact is closed in the OK state and opens after the time delay on a fault |
| Input Voltage | 24-240V AC/DC |
| Input Operating Range | -15% / +10%; AC 50-60 Hz |
| Trip Delay | 0.5-10 s adjustable |
| Sensing Delay on Power-Up | 0.3 s |
| Setting Accuracy | 5% (mechanical setting); repeat accuracy <1%; temperature dependency <0.1%/°C |
| Hysteresis | 5% (functions O1, U1, W); Imax - Imin (functions O2, U2) |
| Reset Method | Automatic; latching functions (OL, UL, WL) reset by a short interruption of the supply or by turning the function switch to R |
| Status Indicator | LEDs for supply voltage and operating status (flashing during the time delay) |
| Contact Configuration | SPDT |
| Number of Poles | 1 |
| Output Rating | 13 A AC1 / 13 A general purpose at 250 V AC (55 °C); breaking capacity 4000 VA AC1, 384 W DC1; switching voltage 250 V AC / 24 V DC |
| Mounting Type | DIN Rail |
| Module Width (mm) | 17.6 |
| Dimensions | 90 x 17.6 x 64 mm (3.5 x 0.7 x 2.5 in) |
| Rated Power | 3.8 VA / 0.7 W max |
| Operating Temperature (Storage) | -20...+55 °C (-30...+70 °C) |
| Mechanical Life | 10,000,000 (100,000) |
| Approvals | cULus Listed, Industrial Control Equipment 496Y; CE |